APEX Destiny 6100 Alarm Panel 

Product Information 

 

Product Information 

The PhastLink Interface 

The PhastLink interface allows the APEX Destiny 6100 Alarm Panel to function as 
a fully integrated device in a PHAST Landmark™ system. This level of integration 
allows drag-and-drop programming of device features in Landmark Designer 
software, active data display on system keypads, and ease of installation and use. 

PhastLink provides a powerful and flexible way to connect devices to a control 
network that can span large homes and even commercial installations. PhastLink 
uses standard physical hardware found in 10Base-T Ethernet networks, like 
Category 5 wire and RJ-45 connectors, and is compatible with several industry-
standard structured wiring specifications and standards.  

PhastLink also provides individual dynamic device addresses, high-speed data 
transmission, and extended cable lengths using advanced hub technology. 
Typically up to 10 devices may be chained together in a single run of up to 1,000 
feet. An unlimited number of individual appliances may be connected via multiple 
hubs. 

PhastLink Interface Communications 

PhastLink communication with the APEX Destiny 6100 Alarm Panel is handled by 
the APEX PhastLink Board, which is mounted on the APEX Control Board, as 
shown in Figure 1. Connection to the Landmark system is via PhastLink cables 
that use standard RJ-45 connectors. 

 

Figure 1 

Connecting to a APEX 

PhastLink Board on the APEX 

Control Board. 

Содержание APEX Destiny 6100

Страница 1: ...instruction manual Landmark Products APEX Destiny 6100 Alarm Panel ...

Страница 2: ... liability applies whether damages are sought or a claim is made under this warranty or as a tort claim including negligence and strict product liability a contract claim or any other claim This limitation of liability cannot be waived or amended by any person This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised ...

Страница 3: ...The PhastLink Interface 1 PhastLink Interface Communications 1 Installation and Wiring 3 PhastLink Cable Information 4 Connecting to a Cardframe or Hub 5 Building a double 120 ohm terminator 5 Programming 7 Programming Options 9 Events 9 Commands 9 Conditionals 10 Menus 10 Troubleshooting 13 ...

Страница 4: ...ii Table of Contents APEX Destiny 6100 Alarm Panel ...

Страница 5: ...networks like Category 5 wire and RJ 45 connectors and is compatible with several industry standard structured wiring specifications and standards PhastLink also provides individual dynamic device addresses high speed data transmission and extended cable lengths using advanced hub technology Typically up to 10 devices may be chained together in a single run of up to 1 000 feet An unlimited number ...

Страница 6: ...2 Product Information APEX Destiny 6100 Alarm Panel ...

Страница 7: ...he APEX panel 6 If the Landmark system is on and functioning and the PhastLink connection is established a small green LED should be illuminated on the APEX PhastLink Board This indicates that the APEX panel is communicating with the PhastLink network If serial communication has been properly configured for the APEX panel the small red LED on the APEX PhastLink Board should be illuminated When pac...

Страница 8: ...r and Figure 3 gives pinout information 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 RJ 45 Socket RJ 45 Plug RJ 45 Pinout Information Pin Wire Color Polarity Function 1 White Green Transmit 2 Green Transmit 3 White Orange Mic 4 Blue Ground 5 White Blue 12VDC 6 Orange Mic 7 White Brown Receive 8 Brown Receive PhastLink uses a standard 10Base T connection i e Category 5 wire and RJ 45 connectors The wire should ...

Страница 9: ... devices to be daisy chained on one PhastLink port Refer to the PLB CF10 documentation for more detailed connection information The limit for each home run is 10 PhastLink devices Extra hubs can be added to provide additional ports For optimum performance PHAST recommends the installation of a double 120 ohm terminator in one of the RJ 45 jacks of the last device or the only device in a chain of P...

Страница 10: ...or a separate microphone line for each keypad they cannot be daisy chained to other LCD keypads they can however be daisy chained with other PhastLink devices When connecting PHAST keypads that will be used as intercoms the Microphone Hub taps off the intercom audio signal carried on the PhastLink cable from that keypad PhastLink devices cannot be wired in a star configuration ...

Страница 11: ...ystem devices This creates an APEX Alarm zone in the project 4 Have Landmark Designer Specify Hardware for the project after adding an APEX device This adds an APEX Destiny 6100 Alarm Panel to the project 5 Carry out the network assignment steps for each APEX Destiny 6100 Alarm Panel as follows a Click on the Network task button b Select the Attachments tab c Select the appropriate APEX Destiny 61...

Страница 12: ...Default is 1 7 Test the setup from the Control tab of an APEX device For example double click a door sensor icon select the Control tab and click on the Status button to check for successful communication between Landmark and the APEX panel The system should react as if an APEX keypad s Status button was pressed 8 Program the way that the APEX devices function within the Landmark system in the sam...

Страница 13: ...selected partition is armed to Away Arm to Night Arm event fires when the partition is armed to Night mode Arm to Home Arm event fires when partition is armed to Home In addition to Arm and Zone events the following system events will fire when the associated physical event occurs Arm Disarm Exterior Instant Exterior Delay 1 Exterior Delay 2 Interior Instant Interior Delay 1 Interior Delay 2 Resto...

Страница 14: ...the zone conditionals the following system conditionals will evaluate to TRUE after the associated physical event occurs Arm Disarm Exterior Instant Exterior Delay 1 Exterior Delay 2 Interior Instant Interior Delay 1 Interior Delay 2 Restore Fire Panic Silent Emergency Duress AC Fail AC Restore Fuse Trouble Fuse Restore Arm With Zones open Low Battery Battery Restore Fail to Arm Fail to Disarm Exp...

Страница 15: ...d 2 key Apex 3 Apex keypad 3 key Apex 4 Apex keypad 4 key Apex 5 Apex keypad 5 key Apex 6 Apex keypad 6 key Apex 7 Apex keypad 7 key Apex 8 Apex keypad 8 key Apex 9 Apex keypad 9 key Apex A Apex keypad Arm key Apex H Apex keypad Home key Apex Fire Apex keypad Fire key Apex Panic Apex keypad Panic key Apex Emergency Apex keypad Emergency key Figure 9 Autogenerating Menu Items for PHAST DMS and IMS ...

Страница 16: ...12 Programming APEX Destiny 6100 Alarm Panel ...

Страница 17: ...indicates that data is not being sent or received through the APEX PhastLink Board If the green LED on the APEX PhastLink Board is NOT illuminated make sure the Landmark system is running follow the PhastLink cable back to the PhastLink hub or cardframe and check the RJ 45 connections as described in the PhastLink Cable Information sub section If the green LED IS illuminated the problem may be due...

Страница 18: ...ive richardson TX 75082 USA 469 624 8000 800 222 0193 fax 469 624 7153 technical support 800 932 6993 051 004 1711 8 01 2001 AMX Corporation All rights reserved AMX the AMX logo the building icon the home icon and the light bulb icon are all trademarks of AMX Corporation AMX reserves the right to alter specifications without notice at any time In Canada doing business as Panja Inc ...

Отзывы: