E
77
2013 SmartBox
®
System Troubleshooting
Problem
Possible Cause
Controller
Message
Possible
Solution
No communication Power to distribution
box
No communication
with distribution box
Check all cable
connections
No communication
No power
No communication
with distribution box
Connect to battery
or replace fuse
No response from
meters
System not
configured yet
No response from
meters
Complete Row
Configuration
No response
5 ft. adapter cable
not attached
No response from
meters
Connect adapter
cable
No response from
meters
Row harness not
attached
No response from
meters
Attach row harness
Unable to configure
full system
Not all row
harnesses attached
Attach next row
Connect row
harness(es)
Unable to configure
full system
Incorrect number of
rows entered
Operate
Reset row number
and reconfigure
Individual rows not
responding
Meters not attached
No response from
row number
Attach the row
Individual rows not
responding
Cut row cable
Meter not responding Fix or replace row
cable
Individual meter not
responding
Bad meter
Meter # not respond-
ing
Replace and
configure new
meter
Содержание SmartBox
Страница 1: ...Parts and Operator s Manual ...
Страница 5: ...4 A ...
Страница 32: ...31 A Suggested 16 Row Planter Arrangement Diagram ...
Страница 33: ...32 A Suggested 36 Row Planter Arrangement Diagram ...
Страница 34: ...33 A Suggested 16 Twin Row Planter Arrangement Diagram ...
Страница 35: ...34 A Wiring Diagram Parts ...
Страница 57: ...56 B Speed Input Setup continued ...
Страница 59: ...58 B Grouping continued ...
Страница 68: ...67 D ...
Страница 74: ...73 D Sensor Enable Disable ...
Страница 75: ...D 74 Weather Info ...
Страница 77: ...D 76 Area Information ...