If a steel hydropneumatic tank is in place, replace it with a properly sized diaphragm 

expansion tank. Otherwise, significant heat transfer problems can occur by causing air to 

be trapped in the heat exchanger. If the boiler system has an existing expansion tank and the boiler temperatures 

are being changed, resize the existing diaphragm expansion tank.

Use care when using a torch near the top cover and heat exchanger plate. It is recommended 

that the front half be removed prior to soldering to avoid potential damage.

3. Required Components And

Accessories Checklist

Boiler Return

Cold Water

Inlet

Retaining Screws (2)

Heat Trap

Boiler Supply

Hot Water 

Outlet

15

10

5

0

0

2

4

6

8

Head Loss (Feet)

Flow (Gallons Per Minute)

HYDROMAX

®

 Components 

(Single Wall Shown)

Two-Piece Cover Removal and Installation

Heat Exchanger Pressure Loss

MODEL

CIRCULATOR 

PERFORMANCE ZONE VALVE

SHUTOFF 

VALVES

RELIEF VALVE

THERMAL 

EXPANSION 

TANK

HM-41

4 GPM @ 6 FT

3/4" Full Port

4

Included

2.0 Gallon

HM-80

4 GPM @ 6 FT

3/4" Full Port

4

Included

4.4 Gallon

Removing Front Half:

Depress both tab buttons to 

detach one side at a time.

Installing Front Half:

Align bottom groove of cover

onto metal retaining ring.

Beginning with one side,

align pin and push until both

tabs lock. Repeat for other

side, ensuring all tabs are

fully engaged.

Removing Entire Cover:

Remove front half, loosen 

both retaining screws and

remove rear half.

Tab Buttons (4)

Содержание HYDROMAX HM-41

Страница 1: ...The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1 as listed in Clinical Toxicology of Commercial Products 5th edition The pressure of the heat trans...

Страница 2: ...t the same time the water heater may not be supplied with enough hot boiler water to recover adequately The delivery of domestic hot water will be diminished In many but not all cases this is not a pr...

Страница 3: ...etaining Screws 2 Heat Trap Boiler Supply Hot Water Outlet 15 10 5 0 0 2 4 6 8 Head Loss Feet Flow Gallons Per Minute HYDROMAX Components Single Wall Shown Two Piece Cover Removal and Installation Hea...

Страница 4: ...rwise penetrate the steel outer tank shell Do not screw pipe hangers or other hardware into the exterior of the tank BOILER PIPING 1 Plumb the circulator or zone valve on the BOILER SUPPLY line 2 Pipe...

Страница 5: ...duit metal clad cable or raceways Power Limited Circuit Cable needed not be provided with the protection specified above if it is securely fastened to the appliance jacket and follows the contour of t...

Страница 6: ...B C1 C2 L2 ORANGE ORANGE WHITE BLACK BLUE BLUE VIOLET VIOLET POWER BURNER PUMP PRIORITY HYDROMAX CIRCULATOR HEATING CIRCULATOR L1 B B2 Z W C1 C2 L2 Millivolt HYDROMAX CIRCULATOR HEATING CIRCULATOR ORA...

Страница 7: ...capacity select appropriate size for proper operation Default is 41 Gallons 26 41 60 80 120 BTU Transfer Real time BTU transfer estimate in 1000 BTU Hr increments Diagnostic readout only 0 199MBH Hr A...

Страница 8: ...l Gas Valves Non Priority AQUASTAT ZONE VALVE MOTOR 24VAC END SWITCH TRANSFORMER L1 L2 4 Wire AQUASTAT Boiler Control Input HYDROMAX CIRCULATOR OR ZONE VALVE DHW ZONE Boiler Controls Zone Valves Unive...

Страница 9: ...faucet 1 Poor water quality 2 Sediment or suspended particles 1 Have water tested for contaminants 2 Install sediment filter purge unit more often to avoid future problems Boiler will not operate whe...

Страница 10: ...obtained at the place of purchase Use proper safety equipment when installing EXPLOSION HAZARD The pressure of the heat transfer medium must be limited to a maximum of 30 psig by an approved safety or...

Страница 11: ...ing Panel Mechanical Control 4 2704R498 2704R498 Ener G NET Digital Temperature Control 5 940R2 940R2 Temperature Sensor Thermistor 2704 259 2704 259 Mechanical Temperature Control 6 2704 093 2704 093...

Страница 12: ...2015 AMTROL Inc Part 9040 694 11 15 1400 Division Road West Warwick RI 02893 USA T 800 426 8765 F 800 293 1519 www amtrol com...

Отзывы: