background image

-6-

Ener-G-NET

 Wiring

Common wiring diagrams are shown below. Select the appropriate diagram for the application. Diagrams are popular examples 

only. If your application is not shown, contact Amtrol Technical Support at 401.535.1216. 

NOTE:

 Ensure the Ener-G-NET installation 

is within the following application and operating parameters:

•  Ambient temperature from 38° to 125°F.

•  Relative humidity ranging from 20% to 90% (non-condensing).

•  Boiler load rating up to 15A resistive, 1/4hp inductive @ 120VAC.

•  Circulator load rating up to 15A, 1/4hp inductive @ 120VAC.

•  Space heating load rating up to 8A @ 120VAC.

HYDROMAX

®

CIRCULATOR

HEATING

CIRCULATOR

ORANGE

ORANGE

WHITE

BLACK

BLUE

BLUE

VIOLET

VIOLET

POWER BURNER

PUMP

PRIORITY

ZR Input Terminal

L1

ZR

C1

C2

L2

HYDROMAX

CIRCULATOR

HEATING

CIRCULATOR

ORANGE

ORANGE

WHITE

BLACK

BLUE

BLUE

VIOLET

VIOLET

POWER BURNER

PUMP

PRIORITY

24 Volt

L1

B

Z

W

C1

C2

L2

HYDROMAX

®

CIRCULATOR

HEATING

CIRCULATOR

ORANGE

ORANGE

WHITE

BLACK

BLUE

BLUE

VIOLET

VIOLET

POWER BURNER

PUMP

PRIORITY

High Limit (B Terminal)

L1

B

C1

C2

L2

ORANGE

ORANGE

WHITE

BLACK

BLUE

BLUE

VIOLET

VIOLET

POWER BURNER

PUMP

PRIORITY

HYDROMAX

®

CIRCULATOR

HEATING

CIRCULATOR

L1

B

B2

Z

W

C1

C2

L2

Millivolt

HYDROMAX

®

CIRCULATOR

HEATING

CIRCULATOR

ORANGE

ORANGE

WHITE

BLACK

BLUE

BLUE

VIOLET

VIOLET

POWER BURNER

PUMP

PRIORITY

Triple-Aquastat

L1

B

R

C1

C2

L2

HYDROMAX

®

CIRCULATOR

HEATING

CIRCULATOR

ORANGE

ORANGE

WHITE

BLACK

BLUE

BLUE

VIOLET

VIOLET

POWER BURNER

PUMP

PRIORITY

L1

B

B2

C1

C2

L2

Self-Generating

Oil Burner Controls

Gas Valve Controls

Other Applications

HYDROMAX

®

CIRCULATOR

DHW ZONE

ORANGE

ORANGE

WHITE

BLACK

BLUE

BLUE

VIOLET

VIOLET

POWER BURNER

PUMP

PRIORITY

Multi-Zone Control: Using Post Purge

L1

L2

TO BOILER

X

X

HYDROMAX

®

CIRCULATOR

OR ZONE VALVE

DHW ZONE

24 OR 120VAC

ORANGE

ORANGE

WHITE

BLACK

BLUE

BLUE

VIOLET

VIOLET

POWER BURNER

PUMP

PRIORITY

Multi-Zone Control: No Post Purge

L1

L2

TO BOILER

X

X

HYDROMAX

®

CIRCULATOR

Z

I

ORANGE

ORANGE

WHITE

BLACK

BLUE

BLUE

VIOLET

VIOLET

POWER BURNER

PUMP

PRIORITY

Outdoor Reset/Automatic Temperature Control

L1

ZC

ZR

L2

ZONE/INDRIECT SWITCH

(IF EQUIPPED)

SELECT “INDIRECT”

ZONE VALVE

END

SWITCH

MOTOR

24VAC

ORANGE

ORANGE

WHITE

BLACK

BLUE

BLUE

VIOLET

VIOLET

POWER BURNER

PUMP

PRIORITY

4-Wire Zone Valve

TRANSFORMER

L1

L2

Содержание HYDROMAX HM-41

Страница 1: ...The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1 as listed in Clinical Toxicology of Commercial Products 5th edition The pressure of the heat trans...

Страница 2: ...t the same time the water heater may not be supplied with enough hot boiler water to recover adequately The delivery of domestic hot water will be diminished In many but not all cases this is not a pr...

Страница 3: ...etaining Screws 2 Heat Trap Boiler Supply Hot Water Outlet 15 10 5 0 0 2 4 6 8 Head Loss Feet Flow Gallons Per Minute HYDROMAX Components Single Wall Shown Two Piece Cover Removal and Installation Hea...

Страница 4: ...rwise penetrate the steel outer tank shell Do not screw pipe hangers or other hardware into the exterior of the tank BOILER PIPING 1 Plumb the circulator or zone valve on the BOILER SUPPLY line 2 Pipe...

Страница 5: ...duit metal clad cable or raceways Power Limited Circuit Cable needed not be provided with the protection specified above if it is securely fastened to the appliance jacket and follows the contour of t...

Страница 6: ...B C1 C2 L2 ORANGE ORANGE WHITE BLACK BLUE BLUE VIOLET VIOLET POWER BURNER PUMP PRIORITY HYDROMAX CIRCULATOR HEATING CIRCULATOR L1 B B2 Z W C1 C2 L2 Millivolt HYDROMAX CIRCULATOR HEATING CIRCULATOR ORA...

Страница 7: ...capacity select appropriate size for proper operation Default is 41 Gallons 26 41 60 80 120 BTU Transfer Real time BTU transfer estimate in 1000 BTU Hr increments Diagnostic readout only 0 199MBH Hr A...

Страница 8: ...l Gas Valves Non Priority AQUASTAT ZONE VALVE MOTOR 24VAC END SWITCH TRANSFORMER L1 L2 4 Wire AQUASTAT Boiler Control Input HYDROMAX CIRCULATOR OR ZONE VALVE DHW ZONE Boiler Controls Zone Valves Unive...

Страница 9: ...faucet 1 Poor water quality 2 Sediment or suspended particles 1 Have water tested for contaminants 2 Install sediment filter purge unit more often to avoid future problems Boiler will not operate whe...

Страница 10: ...obtained at the place of purchase Use proper safety equipment when installing EXPLOSION HAZARD The pressure of the heat transfer medium must be limited to a maximum of 30 psig by an approved safety or...

Страница 11: ...ing Panel Mechanical Control 4 2704R498 2704R498 Ener G NET Digital Temperature Control 5 940R2 940R2 Temperature Sensor Thermistor 2704 259 2704 259 Mechanical Temperature Control 6 2704 093 2704 093...

Страница 12: ...2015 AMTROL Inc Part 9040 694 11 15 1400 Division Road West Warwick RI 02893 USA T 800 426 8765 F 800 293 1519 www amtrol com...

Отзывы: