5
Uncrating/Installation Instructions
122993-618
1. Review installation requirements:
a. Clearance - Clearance space shown on Equipment Drawing is
necessary for easy installation and proper operation and
maintenance of washer.
b. Barrier wall flange(s) installation - Refer to Equipment Draw-
ing for barrier wall installation.
c. Utility service lines:
•
To allow service on unit without shutting off building supply
lines, shutoff valves (not by STERIS) should be installed on
steam, air and water lines to unit (see Figure 4). Shutoff
valves must be capable of being locked in the OFF position
only.
•
Disconnect switch (not by STERIS) must be installed in
electric supply line near washer (see Figure 4). Disconnect
switch must be capable of being locked in the OFF position
only.
•
If this machine is installed next to other equipment, shutoff
valves and disconnect switch should be located so that
service can be shut off to one piece of equipment at a time.
•
Utility service requirements are shown on Equipment
Drawing. This machine requires either 120/208 volts, 60 Hz,
3-phase, 4-wire; or 480 volts, 60 Hz, 3-phase, 3-wire power.
Check Equipment Drawing or Identification Plate (located
inside lower service compartment on bottom of chamber
sump, see Figure 3) for proper voltage.
•
Blow out all utility supply lines to remove chips, scale, etc.
2. Make sure washer is placed, as shown on Equipment Drawing,
in correct relation to building supply lines. If unit is not at
installation site, refer to Uncrating Instructions (Section 2) for
proper moving instructions.
3. Check level of washer.
•
Place a spirit level on top and along side of washer cabinet.
•
Level washer, end-to-end and side-to-side, using leveling legs
located at base of washer.
1. Unlock and remove lower service access panel.
2. Connect the following building supply lines to the washer (see
Figure 5).
•
HOT WATER
- Connect line to washer connection, accessible
from lower service compartment.
NOTE: Water is hot; safely run water line to a sink or drain.
Before Installing
Equipment
Figure 4. Utility Service
Figure 4. Utility Service
Figure 4. Utility Service
Figure 4. Utility Service
Figure 4. Utility Service
Connections
Connections
Connections
Connections
Connections
Installation Instructions
INSTALLATION INSTRUCTIONS
WARNING - BURN HAZARD: When
blowing out utility supply lines,
wear gloves, face shield and pro-
tective clothing.
Connect Utilities
3
L o c k