![Amron 8225-HP Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/amron/8225-hp/8225-hp_instruction-manual_2935939008.webp)
GENERAL INFORMATION
4
LOW PRESSURE ALARM MODULE
2.4
Low Pressure Alarm Module supplies a loud audio signal to alert the operator when a diver's air
pressure falls below a preset limit of 100 PSIG.
COMMUNICATIONS 2.5
The diver communication system is based on the field proven AMRON Model 2825. The unit is
powered from internal rechargeable gel cell batteries, battery charger provided. Operating time from
fully charged battery is approximately 60 hours. Unit can also be operated from an external 12 V DC
source, via charger jacks on the front panel. The communicator has a unique battery condition
indicator; Steady GREEN light indicates battery voltage level is good. Blinking GREEN light
indicates battery voltage is approaching a low level (approx 2-4 hours of operation remain). Steady
RED light indicates battery voltage is below the level necessary to guaranty proper operation.
WARNING:
When Battery Condition indicator is steady RED light, communication will stop. The
battery condition indicator also functions in the same manner when operating from an external power
source.
Possibly the most useful feature of the AMCOMMAND communicator is the ability to operate the unit
remotely. This feature allows the use of a hand held push to talk microphone (included), or a walk
and talk type module (optional). This allows the tender (operator) to move about and still maintain
contact with the divers.
The use of the noise canceling push to talk microphone automatically disconnects the speaker when
talking to the divers cutting out the majority of the background noise, greatly improving the
intelligibility of communications.
The communicator provides 12 watts voice power. This power level provides the volume necessary
to communicate clearly even under difficult conditions. Standard controls include; power on/off,
tender volume, diver volume, speaker on/off, 5-way binding post diver input, push to talk switch,
headset/microphone jack, and remote push to talk jacks.
28/FDW Wireless Tender Option
Models 8225-HP/28/FDW & 8225-HP2/28/FDW Amcommand II comes with the Amron 2 Diver
Deluxe Communications System with Wireless Tender. This feature allows the tender (operator) to
be completely mobile around the dive sight while still remaining in constant contact with the divers.
The wireless tender is a full duplex (SIMULCOM) system. The system comes complete with a
built-in transceiver module with antenna and one wireless headset with clip-on belt module. The
system allows unlimited headsets for listen only. The unit operates FM at 49 MHz. The range is up
to 1/4 mile and uses one 9 volt battery.
Содержание 8225-HP
Страница 16: ...CONTROLS CONNECTIONS AIR CONTROL FRONT PANEL MODEL 8225 HP 6 3 12...
Страница 18: ...CONTROLS CONNECTIONS PNEUMO FRONT PANEL MODEL 8225 HP 6 6 14...
Страница 20: ...CONTROLS CONNECTIONS COMMUNICATOR FRONT PANEL MODEL 2825A 8225 6 8 16...
Страница 29: ...OPERATING PROCEDURES DIAGRAM SET UP INSTRUCTIONS Figure 3 8 7 25...
Страница 31: ...OPERATING PROCEDURES DIAGRAM SIMULCOM 4 Wire Connection Model 2825 8225 Figure 4 8 9 27...
Страница 39: ...THEORY OF OPERATION FLOW DIAGRAM MODEL 8225 HP 9 2 35...
Страница 42: ...THEORY OF OPERATION FUNCTIONAL BLOCK DIAGRAM MODEL 2825 8225 9 4 38...
Страница 52: ...REFERENCE MATERIAL DIVING LOG U S NAVY CHART 12 1 48...
Страница 53: ...REFERENCE MATERIAL REPETITIVE DIVE WORKSHEET 12 2 49...
Страница 58: ...DRAWINGS SCHEMATICS SCHEMATIC DIAGRAM MODEL 2825A 8225 13 1 54...
Страница 59: ...DRAWINGS SCHEMATICS PARTS IDENTIFIER 2832 202 13 2 55...
Страница 60: ...DRAWINGS SCHEMATICS SCHEMATIC DIAGRAM 28FDW OPTION 13 3 56...
Страница 61: ...DRAWINGS SCHEMATICS SCHEMATIC PARTS LOCATOR MODEL 2324 202 13 4 57...
Страница 62: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 8225 200 Pneumo Front Panel 13 5 58...
Страница 63: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 8225 200 Pneumo Back Panel 13 6 59...
Страница 64: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 8225 400HP Air Control Front Panel 13 7 60...
Страница 65: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 8225 400HP Air Control Back Panel 13 8 61...
Страница 66: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 8225 400HP2 Air Control Front Panel 13 9 62...
Страница 67: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 8225 400HP2 Air Control Back Panel 13 10 63...
Страница 68: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 2825A 8225 28FDW Diver Communications 13 11 64...
Страница 69: ...DRAWINGS SCHEMATICS 65 PARTS LOCATOR MODEL 8000 0201 Regulator 13 12...