MAINTENANCE
40
SCHEDULED MAINTENANCE- (cont’d)
10.2
Every 12 months, complete the above tests plus the following:
1.
Remove high-pressure valve stems, inspect, clean, lubricate (use Christolube grease,
Amron part No. MCG-111-20Z) and install. Check valve seat, threads, packing material for
signs of wear or deterioration, replace if necessary.
2.
Remove Filter element and inspect. If filter element is dirty make a determination as to
where the contamination is coming from. Check the air source being used to determine
where the contamination is coming from and correct. If filter is contaminated, remove high
pressure section and clean all valves, inspect for signs of wear and deterioration, replace
those parts which show signs of deterioration, clean and reassemble.
3.
Check regulator action, check regulator maximum pressure, should be greater than
265 PSI.
4.
Check relief valve actuation and shut off. Should vent at 285 PSI, close at 280 PSI sealing
bubble tight.
5.
Check action of pneumo gauge protectors, should shut off at 122 PSI +/- 5 lbs., on slow
rising pressure.
6.
Check operation of LOW-PRESSURE alarm adjust if necessary. Should turn on at 100 PSI
+/- 5 lbs., turn off at 110 PSI +/- 5 lbs.
7.
Check all valves for bubble tight shut off. Replace seats as needed.
8.
Leak test all fittings, Pressure test PNEUMO section.
9.
Check accuracy of all gauges.
10.
Record the results of the above tests.
Every three years, in addition to the above test:
1. Replace all soft goods, seals, gaskets and batteries.
2. Record the results of the above tests.
Содержание 8225-HP
Страница 16: ...CONTROLS CONNECTIONS AIR CONTROL FRONT PANEL MODEL 8225 HP 6 3 12...
Страница 18: ...CONTROLS CONNECTIONS PNEUMO FRONT PANEL MODEL 8225 HP 6 6 14...
Страница 20: ...CONTROLS CONNECTIONS COMMUNICATOR FRONT PANEL MODEL 2825A 8225 6 8 16...
Страница 29: ...OPERATING PROCEDURES DIAGRAM SET UP INSTRUCTIONS Figure 3 8 7 25...
Страница 31: ...OPERATING PROCEDURES DIAGRAM SIMULCOM 4 Wire Connection Model 2825 8225 Figure 4 8 9 27...
Страница 39: ...THEORY OF OPERATION FLOW DIAGRAM MODEL 8225 HP 9 2 35...
Страница 42: ...THEORY OF OPERATION FUNCTIONAL BLOCK DIAGRAM MODEL 2825 8225 9 4 38...
Страница 52: ...REFERENCE MATERIAL DIVING LOG U S NAVY CHART 12 1 48...
Страница 53: ...REFERENCE MATERIAL REPETITIVE DIVE WORKSHEET 12 2 49...
Страница 58: ...DRAWINGS SCHEMATICS SCHEMATIC DIAGRAM MODEL 2825A 8225 13 1 54...
Страница 59: ...DRAWINGS SCHEMATICS PARTS IDENTIFIER 2832 202 13 2 55...
Страница 60: ...DRAWINGS SCHEMATICS SCHEMATIC DIAGRAM 28FDW OPTION 13 3 56...
Страница 61: ...DRAWINGS SCHEMATICS SCHEMATIC PARTS LOCATOR MODEL 2324 202 13 4 57...
Страница 62: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 8225 200 Pneumo Front Panel 13 5 58...
Страница 63: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 8225 200 Pneumo Back Panel 13 6 59...
Страница 64: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 8225 400HP Air Control Front Panel 13 7 60...
Страница 65: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 8225 400HP Air Control Back Panel 13 8 61...
Страница 66: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 8225 400HP2 Air Control Front Panel 13 9 62...
Страница 67: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 8225 400HP2 Air Control Back Panel 13 10 63...
Страница 68: ...DRAWINGS SCHEMATICS PARTS LOCATOR MODEL 2825A 8225 28FDW Diver Communications 13 11 64...
Страница 69: ...DRAWINGS SCHEMATICS 65 PARTS LOCATOR MODEL 8000 0201 Regulator 13 12...