C-1. Available Accessories and Options

This manual does not list all possible
accessories that AMPTEC RESEARCH is

willing to provide as a support items for the

AMPTEC 601ES DMM. Contact the sales
department at AMPTEC RESEARCH if you

have a request for an item that is not described
here. Listed below are some of the options

available for use with the AMPTEC 601ES

Explosive Safety DMM.

Option 401: Gold Plated Single Probe Leads

Option "401" is a

handheld probe

(one black probe & one red probe) lead set ter-

minated in

. The OP401 handheld

probes allow for easy access to connector socket

wiring (i.e. drone parachute squib sockets),
recessed surfaces and parts (i.e. flares) that alli-

gator clip leads simply can’t access properly.

Option "401" plated a 4-wire lead set (up to the

probe tip, 2 and 2 style) is terminated with sin-

gle

handheld probe test points. The

“401” also has

dual banana leads

that connect directly to the AMPTEC 601ES
DMM measurement front panel jacks (red and

white). 4-wire Kelvin is maintained up to the

point of the probe tip connection, eliminating
98% of the cable resistance. Gold plated tips

and banana jack ends provide an optimal low

thermal emf connection.

gold plated

single points

gold plated

gold plated

Kelvin Leads, Probes Accessories and

Options

All AMPTEC series test lead and probe sets are
a minimum 48" length, dual banana

termination at the ohmmeter end (call the

Sales Department at AMPTEC RESEARCH
for any custom requirement)

.

Option 403 4 Terminal Kelvin Mini-probes

:

with 0.18" separation, one red and one

black handheld probe. Excellent general purpose

4-Wire Kelvin Mini-Probe, and along with the
Option "300" Kelvin Clip Leads easily fit inside

the AMPTEC test lead pouch.

Each probe has two spring loaded, gold plated,

steel tips

Option 300: 4-Wire Kelvin Lead Set

Recommended for Calibration - Option "300" is a

four wire Kelvin lead set for all

AMPTEC 601ES DMM. Option 300 is a shielded

48" lead set terminating in ½" opening gold plated
copper Kelvin clips. The option "300" can clip

easily to wires, pins and medium size conductors
(up to ½" diameter). The dual banana

gold plated

Option “300”

Close-Up

Option "300"

4-Wire Kelvin Clip Test Lead Set

(Gold Plated)

SECTION C - REPLACEMENT, OPTIONAL
AND ACCESSORY ITEMS

8

Содержание 601ES

Страница 1: ...RESEARCH AMPTEC CALIBRATED MODEL SER NO DATE DUE Tamper ProofSeal Sticker Calibrationvoidifremoved 601ES 601ES 503 05APR2005 05APR2006 I press hold 2 0 KOHM 20 OHM 200 OHM 2 0 OHM 20 KOHM FUNCTION RA...

Страница 2: ...cifications C 1 Available Accessories and Options D 1 General D 2 Front Panel Features and Operation D 3 Complete 601ES Explosive Safety DMM Front Panel Diagram D 4 4 Wire Resistance Measurement 601ES...

Страница 3: ...Procedure F 3 1 Zero Offset Adjustment F 3 2 Full Scale Adjustment F 3 3 2 0 Ohm Range Adjustments F 3 4 Verification of Each Ranges Accuracy F 3 5 AC DC Voltage Adjustments F 3 6 AC DC Current Adjust...

Страница 4: ...osive Safety Igniter Circuit Test industry must be held down for 2 seconds The AMPTEC 601ES DMM Safety Meter has a circuit that indicates when it is time To replace the batteries They can be replaced...

Страница 5: ...ince Nickel Metal Hydrides are re chargeable they offer a battery life cycle a hundred times greater than any alkaline Be sure to charge the Nickel Metal Hydride batteries when taken out of their orig...

Страница 6: ...around the battery holder and secure Cut excess plastic Next wrap the black and red wire around the battery holder and place the holder into the compartment Lastly replace lid and screw in screws to...

Страница 7: ...ange Accuracy 0 50 of range DC or AC RMS range Accuracy 0 50 of range DC or AC RMS range Accuracy 0 50 of range 2 0 Amperes DC or AC RMS range Accuracy 0 50 of range 2 0 Ohm Range thru 20 KOhm ranges...

Страница 8: ...e point of the probe tip connection eliminating 98 of the cable resistance Gold plated tips and banana jack ends provide an optimal low thermal emf connection gold plated single points gold plated gol...

Страница 9: ...banana plugs at one end The other end is terminated with an alligator clip red and black These alligator clips will measure 2 wire method properly with either upper or lower jaw connected to the condu...

Страница 10: ...once the access screws have been removed for calibration These handles are for carrying the 601ES DMM around when the lid is removed They are strictly for calibration access he main Power switch to tu...

Страница 11: ...M is factory set using internal PCB jumpers to automatically turn off after 30 minutes of inactivity no range or function change to conserve battery power 5 Automatic Turn Off Protection Fuse Stray Cu...

Страница 12: ...g the zero knob past the stops will severely damage the precision of the instrument and violate the instruments warranty 2 20 and 200 ohm ranges 10 Case Chassis Ground Jack not tied to earth ground A...

Страница 13: ...s go in continuous decades from 2 0 Ohms to 20 Kilo Ohms The selection of the 2 0 Ohm lowest resistance range is accomplished by rotating the range knob Align indicator mark on knob with the desired r...

Страница 14: ...ck to the AMPTEC 601ES DMM through the jack Depending upon the magnitude of the resistance offset some of the offset may be corrected zero ed out for in the AMPTEC 601ES DMM by adjusting the zero knob...

Страница 15: ...g Circuitry fatigued adapter wire plug wire splice loose the fewer the connections the fewer the problems The LCD display will indicate when it is time to replace the batteries LO BAT LO BAT The The A...

Страница 16: ...atsoever If you turn on display does not come on Explosive Safety DMM m AMPTEC Explosive Safety DMM and the If the AMPTEC 601ES Explosive Safety DMM exhibits problems that cannot be eliminated by revi...

Страница 17: ...only when the integrator is de integrating At the end of a conversion the data remaining in the results counter is latched decoded and multiplexed to the liquid crystal display The analog section blo...

Страница 18: ...n also turn the unit off the same way after a certain time period has elapsed This is to save battery life See FIG H 1 The micro can turn on TR201 TR209 using IC201 and I 202 These fets are used to se...

Страница 19: ...y Out of Specification Section B No adjustments are needed Verify each function and range with the appropriate calibration standards to determine if the AMPTEC 601ES DMM meets its published accuracy s...

Страница 20: ...PCB then later verify 3 4 5 6 7 8 A B C D F 3 6 AC DC Current Adjustments 1 the battery compartment When adjusting RV405 which is indicated as a negative sign Select the 20 Kohm range Connect the Kel...

Страница 21: ...press to measure button and Adjust RV502 and repeat this step 5 dual button press operation until the AMPTEC 601ES reads 0050 A 5 milliamperes Return both the and the s to their standoff PCB mounts Re...

Отзывы: