SIZE 22, 22M, 22D 

 
 
 
 
 
 

SIZE 12, 16, 20 

Contact Preparation Instructions 

 
 

 

I.

 

Crimp Tools:

 

 

1.

 

M22520 Series is recommended. See Tool Table in 
catalog, for choice of turret head and selection setting 
according to contact size, part number and wire gage 
size. 

 

2.

 

Setting Up and Operation: Consult Tool Manufacturer. 

 

II.

 

Wire Preparation and Crimping

 

 

1.

 

Strip wire to required length. (See Figure 1). When 
using hot wire stripping do not wipe melted insulation 
material on wire strands; with mechanical strippers do 
no cut or nick strands. 

 

Figure 1 

 

 

 
 

 
 

 

 

 

 

 

2.

 

See Table 1 for proper finished outside wire dimensions. 

 

Table 1: Conductor Diameters 

Contact 

Size 

Wire Diameters (in.) ** 

Min. 

Max. 

10 

0.135 

0.162 

12 

0.097 

0.142 

16 

0.065 

0.109 

20 

0.040 

0.077 

22 

0.034 

0.060 

22M, 22D 

0.030 

0.050 

 

**Min. diameters to insure moisture proof assembly; max 
diameters to permit use of metal removal tools. Twist Strands 

together to form a form bundle. 

 

3.

 

Insert stripped wire into contact applying slight 
pressure until wire insulation butts against wire well. 
Check inspection hole to see that wire strands are 
visible. If there are strayed wire strands, entire wire 
end should be re-twisted. 

 

4.

 

Insert wire and contact into crimping tool as far as 
possible. Crimp contact wire well. 

 

III.

 

Contact Insertion and Removal

 

 

1.

 

When inserting or removing contacts, first remove 
securing devices and slide devices over wires in 
proper sequence 

 

2.

 

Consult Tool Table, in catalog, for correct insertion or 
removal tool (metal or plastic) according to contact 
size. 

 

3.

 

Insertion: 

 

a.

 

Slip correct size tool (with plastic tool, use colored 
end) over wire insulation and slide forward until tool 
bottoms against rear contact shoulder. Contact must 
be aligned with grommet hole and not inserted at an 
angle. Push forward until contact is felt to snap into 
position within insert. Remove tool, holding forward 
on the wire in order to prevent contact from being 
dragged back with tool. Gently pull each wire to 
ensure contact is properly seated. 

 

b.

 

Uncrimped Contacts and Sealing Plugs: Fill in 
unused holes with an uncrimped contact. Follow with 
a teflon sealing plug, small diameter first, so that one 
end protrudes out the rear of grommet. See Table 2 
for sealing plug application data. (Optional insertion 
of large end first is possible, but not recommended). 

 

Table 2: Sealing Plugs 

Contact Size  Color Code 

Part Number 

10 

Green 

M85049/81-10 

12 

Yellow 

MS27488-12 

16 

Blue 

MS27488-16 

20 

Red 

MS27488-20 

22, 22M, 22D 

Black 

MS27488-22 

Содержание AMPHE-EX L-2124

Страница 1: ...ontents Familiarization Assembly Contact Preparation and Installation Connector Assembly Part Number Code Logic For additional information consult Amphenol AMPHE EX Catalog 12 056 Amphenol EEC Des Pla...

Страница 2: ...ins Alternative keying options Alternative pin or sleeve contacts in either the plug or receptacle bodies Model Code Designations Connectors EXM a b c d e f g h Connector series type designation EXM S...

Страница 3: ...se only the proper crimping tools that have been set or calibrated with precision gages 8 Make certain that all contacts are the correct size before attempting to assemble in insert cavities This poin...

Страница 4: ...l be carried out by suitably trained personnel in accordance with the applicable code of practice e g EN IEC 60079 14 or EN IEC 61241 14 It is the end user s responsibility to ensure that the product...

Страница 5: ...determined to have reached end of life can be removed from equipment and disassembled for recycling Components that are not accepted by recycler are safe to be disposed of with other commercial waste...

Страница 6: ...g this equipment shall be suitable certified as compliant with EN 60079 28 2007 and provide an inherently safe optical source op is EPL Gb subsequently the following parameters apply Application Tempe...

Страница 7: ...should be re twisted 4 Insert wire and contact into crimping tool as far as possible Crimp contact wire well III Contact Insertion and Removal 1 When inserting or removing contacts first remove secur...

Страница 8: ...melts It is important that you hold everything very steady until solder begins to flow After soldering one or two connections clean and re tin the tip Soldering must be done quickly since you can melt...

Страница 9: ...Contacts Remove sealing plugs Standard Removal Tools Using applicable removal tool insert and carefully work tool tips over wire well When tips bottom contact will release from internal retention clip...

Страница 10: ...Page 10 of 17 TYPICAL...

Страница 11: ...e securement of the Cable Gland to the cable adapter and seal compression around the cable jacket In terms of the Amphe Ex series the Cable Adapter is considered an enclosure and should be treated as...

Страница 12: ...ons required to be determined by end user 9 Thread the receptacle assembly into the bulkhead until the seal touches down and then tighten it by the smallest fraction of a revolution to the first insta...

Страница 13: ...down on a table Carefully roll the pouch to force the material on the side being rolled so the material is forced toward the center of theQuik Pak 3 Squeeze the compartment being rolled so that the bu...

Страница 14: ...927 0 877 0 49 17 1 3 1 242 1 575 0 87 19 1 3 1 242 1 575 0 87 21 1 3 1 242 1 575 0 87 Note Minimum amount of potting required Epoxy Volume Per Hermetic Receptacle with Integral Potting Adapter Shell...

Страница 15: ...ed to Bulkhead Receptacle Figure 3 Hermetic Panel Mount Configuration Inline Plug mated to Hermetic Panel Mount Receptacle ATEX or IECEX CERTIFIED CABLE GLAND IP6X RATED WITH SEALS TEMP RATED 20 C TO...

Страница 16: ...anel Mount Receptacle Part Spigot Diameter mm Spigot Length mm EXM a 02 H 9 d e f g 11 95 11 90 21 EXM a 02 H4 9 d e f g 11 95 11 90 21 EXM a 02 H 11 d e f g 14 95 14 90 21 EXM a 02 H4 11 d e f g 14 9...

Страница 17: ...Ta 40 C Ex tb IIIC T80 C Db 40 C Ta 40 C IP6X II 2 G D Ex db IIC T5 Gb 40 C Ta 55 C Ex op pr IIC T5 Gb 40 C Ta 55 C Ex tb IIIC T95 C Db 40 C Ta 55 C IP6X II 2 G D Ex db IIC T5 Gb 40 C Ta 55 C Ex op i...

Отзывы: