Page 12 of 17 

 

4)

 

Populate the insert with contacts by poking each of the wired contacts into its respective insert 
cavity, following an electrical schematic for the system being wired. 

5)

 

Slide the Bulkhead Adapter back down the conductors, apply thread locking compound (Loc-tite 
242, blue, non-permanent, or equal), per the compound suppliers recommendations. 

6)

 

Hand-tighten the Bulkhead Adapter onto the Panel Mount Receptacle Shell, then, using a strap 
wrench, tighten the Bulkhead Adapter fully to shoulder. 

7)

 

Referring to the Potting Instructions, Pg 10, stand the assembly vertical, conductors pointing up, 
and fill the Potting Adapter with cement to the level shown in Figure Z. After curing, this 
assembly is now permanently cemented, non-separable and non-repairable, and can be mounted to 
the bulkhead. 

8)

 

It is best to fit the connector to the bulkhead at a time when the free end of the cable is not 
terminated to the electrical system. If this is not possible, then it is necessary to rotate the 
connector assembly counter-clockwise to wind the cable/conductors so that when the assembly is 
threaded into a bulkhead in the subsequent instruction, the cable/conductors regain their most 
natural lay, once the connector is mounted to the bulkhead. (Rotations required to be determined 
by end-user). 

9)

 

Thread the receptacle assembly into the bulkhead until the seal touches down, and then tighten it 
by the smallest fraction of a revolution to the first instance that the mounting holes line up with the 
threaded enclosure holes. 

10)

 

Position the protective covers’ lanyard tab over one of the mounting holes and screw a fastener 
through it. Apply the remaining fasteners to the other three holes with torque suitable for screw 
size used. 

11)

 

Install the protective cover and tighten fully. 

12)

 

Secure both grub screws to prevent unauthorized removal. 

 
 

 

AMPHE-EX

 

Potting Instructions 

All cable adapters, other than ones suited for mating with an EX-certified gland, must be filled with epoxy (potted). 
The material certified for use in filling the connectors in this series, is Epoxies Etc., 50-3150FR/Cat190. The user or 
installer shall consider the performance of these materials with regard to attack by aggressive substances that may be 
present in the hazardous area. This material is a two-component casting system with a 100:5 volumetric mix ratio. 
Hermetic receptacle version employs HYSOL EE4183-HD3404. This material is a two-component casting system 
with a 100:9 volumetric mix ratio. 

 

These products are available in pre-measured “mix & dispense” packaging. More information is available by 
contacting the following authorized suppliers: 

 

Amphenol EEC 
1701 Birchwood Ave. 
Des Plaines, IL 60018 USA 
Phone (773) 463-8343 

Содержание AMPHE-EX L-2124

Страница 1: ...ontents Familiarization Assembly Contact Preparation and Installation Connector Assembly Part Number Code Logic For additional information consult Amphenol AMPHE EX Catalog 12 056 Amphenol EEC Des Pla...

Страница 2: ...ins Alternative keying options Alternative pin or sleeve contacts in either the plug or receptacle bodies Model Code Designations Connectors EXM a b c d e f g h Connector series type designation EXM S...

Страница 3: ...se only the proper crimping tools that have been set or calibrated with precision gages 8 Make certain that all contacts are the correct size before attempting to assemble in insert cavities This poin...

Страница 4: ...l be carried out by suitably trained personnel in accordance with the applicable code of practice e g EN IEC 60079 14 or EN IEC 61241 14 It is the end user s responsibility to ensure that the product...

Страница 5: ...determined to have reached end of life can be removed from equipment and disassembled for recycling Components that are not accepted by recycler are safe to be disposed of with other commercial waste...

Страница 6: ...g this equipment shall be suitable certified as compliant with EN 60079 28 2007 and provide an inherently safe optical source op is EPL Gb subsequently the following parameters apply Application Tempe...

Страница 7: ...should be re twisted 4 Insert wire and contact into crimping tool as far as possible Crimp contact wire well III Contact Insertion and Removal 1 When inserting or removing contacts first remove secur...

Страница 8: ...melts It is important that you hold everything very steady until solder begins to flow After soldering one or two connections clean and re tin the tip Soldering must be done quickly since you can melt...

Страница 9: ...Contacts Remove sealing plugs Standard Removal Tools Using applicable removal tool insert and carefully work tool tips over wire well When tips bottom contact will release from internal retention clip...

Страница 10: ...Page 10 of 17 TYPICAL...

Страница 11: ...e securement of the Cable Gland to the cable adapter and seal compression around the cable jacket In terms of the Amphe Ex series the Cable Adapter is considered an enclosure and should be treated as...

Страница 12: ...ons required to be determined by end user 9 Thread the receptacle assembly into the bulkhead until the seal touches down and then tighten it by the smallest fraction of a revolution to the first insta...

Страница 13: ...down on a table Carefully roll the pouch to force the material on the side being rolled so the material is forced toward the center of theQuik Pak 3 Squeeze the compartment being rolled so that the bu...

Страница 14: ...927 0 877 0 49 17 1 3 1 242 1 575 0 87 19 1 3 1 242 1 575 0 87 21 1 3 1 242 1 575 0 87 Note Minimum amount of potting required Epoxy Volume Per Hermetic Receptacle with Integral Potting Adapter Shell...

Страница 15: ...ed to Bulkhead Receptacle Figure 3 Hermetic Panel Mount Configuration Inline Plug mated to Hermetic Panel Mount Receptacle ATEX or IECEX CERTIFIED CABLE GLAND IP6X RATED WITH SEALS TEMP RATED 20 C TO...

Страница 16: ...anel Mount Receptacle Part Spigot Diameter mm Spigot Length mm EXM a 02 H 9 d e f g 11 95 11 90 21 EXM a 02 H4 9 d e f g 11 95 11 90 21 EXM a 02 H 11 d e f g 14 95 14 90 21 EXM a 02 H4 11 d e f g 14 9...

Страница 17: ...Ta 40 C Ex tb IIIC T80 C Db 40 C Ta 40 C IP6X II 2 G D Ex db IIC T5 Gb 40 C Ta 55 C Ex op pr IIC T5 Gb 40 C Ta 55 C Ex tb IIIC T95 C Db 40 C Ta 55 C IP6X II 2 G D Ex db IIC T5 Gb 40 C Ta 55 C Ex op i...

Отзывы: