ATEX or IECEX CERTIFIED CABLE GLAND, IP6X RATED, 

WITH SEALS TEMP RATED 

-20°C TO +85°C MIN, (WHERE -

40°C≤Ta≤+40°C)

 

-20°C TO +100°C MIN, (WHERER -

40°C≤Ta≤+55°C)

 

Epoxy Volume Per Bulkhead Adapter 

 

Shell 
Size 

Fill Length 
inside Adapter 
(inches) 

Adapter 
Diameter 
(inches) 

Internal 
Volume 
(in ^ 3) 

Internal 
Volume* 
(ounces) 

1.3 

0.652 

0.434 

0.24 

11 

1.3 

0.652 

0.434 

0.24 

13 

1.3 

0.927 

0.877 

0.49 

15 

1.3 

0.927 

0.877 

0.49 

17 

1.3 

1.242 

1.575 

0.87 

19 

1.3 

1.242 

1.575 

0.87 

21 

1.3 

1.242 

1.575 

0.87 

 

Note: * Minimum amount of potting required. 

 

 

Epoxy Volume Per Hermetic Receptacle with Integral Potting Adapter 

 

Shell 
Size 

Fill Length 
inside Adapter 
(inches) 

Adapter 
Diameter 
(inches) 

Internal 
Volume 
(in ^ 3) 

Internal 
Volume* 
(ounces) 

0.93 

0.364 

0.096 

0.053 

11 

0.93 

0.481 

0.168 

0.093 

13 

0.93 

0.533 

0.207 

0.115 

15 

0.93 

0.658 

0.315 

0.175 

17 

0.93 

0.833 

0.505 

0.280 

19 

0.93 

0.950 

0.657 

0.364 

21 

0.93 

1.077 

0.844 

0.468 

 

Note: * Minimum amount of potting required. 

 
 
 
 
 
 

 

Figure 1: Inline Configuration: Plug mated to Receptacle. 

Содержание AMPHE-EX L-2124

Страница 1: ...ontents Familiarization Assembly Contact Preparation and Installation Connector Assembly Part Number Code Logic For additional information consult Amphenol AMPHE EX Catalog 12 056 Amphenol EEC Des Pla...

Страница 2: ...ins Alternative keying options Alternative pin or sleeve contacts in either the plug or receptacle bodies Model Code Designations Connectors EXM a b c d e f g h Connector series type designation EXM S...

Страница 3: ...se only the proper crimping tools that have been set or calibrated with precision gages 8 Make certain that all contacts are the correct size before attempting to assemble in insert cavities This poin...

Страница 4: ...l be carried out by suitably trained personnel in accordance with the applicable code of practice e g EN IEC 60079 14 or EN IEC 61241 14 It is the end user s responsibility to ensure that the product...

Страница 5: ...determined to have reached end of life can be removed from equipment and disassembled for recycling Components that are not accepted by recycler are safe to be disposed of with other commercial waste...

Страница 6: ...g this equipment shall be suitable certified as compliant with EN 60079 28 2007 and provide an inherently safe optical source op is EPL Gb subsequently the following parameters apply Application Tempe...

Страница 7: ...should be re twisted 4 Insert wire and contact into crimping tool as far as possible Crimp contact wire well III Contact Insertion and Removal 1 When inserting or removing contacts first remove secur...

Страница 8: ...melts It is important that you hold everything very steady until solder begins to flow After soldering one or two connections clean and re tin the tip Soldering must be done quickly since you can melt...

Страница 9: ...Contacts Remove sealing plugs Standard Removal Tools Using applicable removal tool insert and carefully work tool tips over wire well When tips bottom contact will release from internal retention clip...

Страница 10: ...Page 10 of 17 TYPICAL...

Страница 11: ...e securement of the Cable Gland to the cable adapter and seal compression around the cable jacket In terms of the Amphe Ex series the Cable Adapter is considered an enclosure and should be treated as...

Страница 12: ...ons required to be determined by end user 9 Thread the receptacle assembly into the bulkhead until the seal touches down and then tighten it by the smallest fraction of a revolution to the first insta...

Страница 13: ...down on a table Carefully roll the pouch to force the material on the side being rolled so the material is forced toward the center of theQuik Pak 3 Squeeze the compartment being rolled so that the bu...

Страница 14: ...927 0 877 0 49 17 1 3 1 242 1 575 0 87 19 1 3 1 242 1 575 0 87 21 1 3 1 242 1 575 0 87 Note Minimum amount of potting required Epoxy Volume Per Hermetic Receptacle with Integral Potting Adapter Shell...

Страница 15: ...ed to Bulkhead Receptacle Figure 3 Hermetic Panel Mount Configuration Inline Plug mated to Hermetic Panel Mount Receptacle ATEX or IECEX CERTIFIED CABLE GLAND IP6X RATED WITH SEALS TEMP RATED 20 C TO...

Страница 16: ...anel Mount Receptacle Part Spigot Diameter mm Spigot Length mm EXM a 02 H 9 d e f g 11 95 11 90 21 EXM a 02 H4 9 d e f g 11 95 11 90 21 EXM a 02 H 11 d e f g 14 95 14 90 21 EXM a 02 H4 11 d e f g 14 9...

Страница 17: ...Ta 40 C Ex tb IIIC T80 C Db 40 C Ta 40 C IP6X II 2 G D Ex db IIC T5 Gb 40 C Ta 55 C Ex op pr IIC T5 Gb 40 C Ta 55 C Ex tb IIIC T95 C Db 40 C Ta 55 C IP6X II 2 G D Ex db IIC T5 Gb 40 C Ta 55 C Ex op i...

Отзывы: