Epoxy Volume Per Bulkhead Adapter
Shell
Size
Fill Length
inside Adapter
(inches)
Adapter
Diameter
(inches)
Internal
Volume
(in ^ 3)
Internal
Volume*
(ounces)
9
1.3
0.652
0.434
0.24
11
1.3
0.652
0.434
0.24
13
1.3
0.927
0.877
0.49
15
1.3
0.927
0.877
0.49
17
1.3
1.242
1.575
0.87
19
1.3
1.242
1.575
0.87
21
1.3
1.242
1.575
0.87
Note: * Minimum amount of potting required.
Epoxy Volume Per Hermetic Receptacle with Integral Potting Adapter
Shell
Size
Fill Length
inside Adapter
(inches)
Adapter
Diameter
(inches)
Internal
Volume
(in ^ 3)
Internal
Volume*
(ounces)
9
0.93
0.364
0.096
0.053
11
0.93
0.481
0.168
0.093
13
0.93
0.533
0.207
0.115
15
0.93
0.658
0.315
0.175
17
0.93
0.833
0.505
0.280
19
0.93
0.950
0.657
0.364
21
0.93
1.077
0.844
0.468
Note: * Minimum amount of potting required.