AMPEON AMP-Series
~20~
0003H
The count of detected metal
D. Debugging and usage maintenance
1
、
Fire alarm simulation test
a. You can use the fire alarm testing function brought by the machine itself .See
Chapter C Using of the control panel/2.3 Function setting/ 4Spark test.
b. There is an active window on the pipe beside the spark diverter. You can also
shine the spark detector through the window by torch. If the controller can carry out
normal action, the spark diverter function is good.
(
The tungsten filament of the
torch is a hot body and includes infrared ray
)
When the fire alarm function is
activated, it is necessary to reset manually.
c. During the normal use, if fire alarm happens, the fan and other machinery’s
operation can not be started until the cause is found out. Occasionally although the
spark is small but it can be out by itself, we should also stop for not less than half an
hour, and we can not start until it is inspected and the safety can be assured.
Warning:
① The spark alarm function should be checked regularly with simulation
test to assure that they are in the good working status. It is suggested that the
test be carried out at least once every two weeks.
② The dust and fibers on the surface of lens in spark detectors must be
regularly checked and cleaned.
2
、
Metal diverting function test and adjustment
In the meantime of metal diverting function test, it is necessary to do the setting
of parameters such as sensitivity, activate, reset and so on.
a. ‘Sensitivity’ setting on the control panel can control the sensitivity of detecting
metal scraps. The higher the sensitivity is, the more sensitive the metal sensor has.
You can set the sensitivity according to the actual needs.
b. ‘Activate’ parameter can adjust the delay time from the metal detector detects
the metal to the diverter activated. Thus the parameter is adjusted to minimum
0.00S,and after many times of testing, it is proved to be able to discharge metal
scraps correctly. This status indicates that the distance from the metal detector to
the diverter is the shortest and it is the most ideal.
c. ‘Reset’ parameter refers to the delay time of resetting after the action of the