diverter. The parameter can directly affect the contaminated material volume. It is
best to assure that the metal scraps can be properly discharged but the
contaminated material volume is the minimum.
d. While you is carrying out the metal test, please be observant to avoid the
metal from entering the blower in the next procedure. You can use spreader tinfoil
not less than 1cm
2
, otherwise 3mm or smaller screw washer with obvious
identification. Then wrap it with cotton and let it be plucked by bale plucker or
directly put it into the transport pipe. When the indicator of the control box lights
and the diverter actuated, that indicates that the metal detection function of this
machine is normal.
e. If the diverter actuated, but you can’t find the test metal in the collecting box,
you should carefully observe and repeatedly adjust Activate and reset parameter
until you can reliably divert the test metal. In the meantime, you should assure the
dropped volume is the minimum. After repeat test, if you still can’t divert properly,
it is necessary to reconsider the install distance from metal detector to diverter.
Activate
3
、
Maintenance and inspections
a. The user should make regular check on the functions of the spark detectors
and metal detector to assure they is in good working state.
b. The material diverted in the collecting box should be emptied timely, or it may
damage the diverter.
c. The diverter should also be checked regularly to make sure in the good state.
Warning:
The power supply and the Compressed air supply should be shut off while
overhauling the diverter. It can insure the user from unexpected hurt by the
movable flap.