4. Technical parameter
a. Sensitivity Metal detection: can detect the steel ball not less than Φ3mm
Spark detection: not less than Φ1mm spark(visual angle not less
than 90 degree)
b. Response time: ≤0.2second
c. Power supply: AC220V±10% ,50HZ
(
Electromagnetic interference conforms
to related standard of our country
)
d. pressure range: 6~8kgf/cm
2
e. Sound level of alarm:
>
120db
f. Power:
<
100VA
g. Relay contact output: 10A/240VAC/28VDC
h. Requirement of the environment: temperature -10
℃
-40
℃
; relative humidity
(
20-75
)
%RH
B. Electric wiring and installing
In order to reach the best performance of AMP-2000V5 type metal & spark
diverter, proper electric wiring and installing is the most important approach. Before
the installing, please read the following carefully and make further measurement and
evaluation properly with respect to installing environment and condition on the site.
1. Electric wiring diagram
a. Diagram of the front part in control
b. Diagram of the hinder part in
box (after the door opens)
control box (after the hinder cover
is removed)