Figure 9: The diagram of several AMP-2000V5regular pipes installing (vertical view)
c. If a bent pipe is installed between metal detector and diverter, the diverting rate
will not reach the ideal effect (refer to figure 9c).So we don’t recommend the
installing method of figure 9c.
d. The center-to-center distance L2of the metal detector to the diverter is the most
important parameter that needs to be confirmed before the installing. The
determination method in detail is as the following table (table 4). L2 directly relates
to the diverting rate.
e. Before the installing, it is necessary to prepare the metal slingers, metal bracket
and wire & cable for the installing.
Air speed ν
(
m/sec
)
Install distance ‘L2’ ( m )
ν
<
10
2m
10
<
ν
<
20
2 m
~
3.5 m
ν
>
20 (high wind speed)
≥4m
(
Adjust according to the actual
situation
)
Table 4: The install distance from metal detector to the diverter
▲Caution!
a) During the installing, the center distance between the metal detector and
diverter L2 is the most important parameter of the installing process. If the install
distance L2 is too long, the metal diverter rate will obviously decrease. The most near
distance that satisfies the simulation experiment L2 is most ideal.
b) After finishing the installing, if you can’t get ideal diverting effect through the