Misoperation happens
frequently in metal
diverting function
4.The fibers rub with
non-metal
pipes
rapidly and the static
electricity happens
4.Observe whether there is
electricity
discharging
between non-metal pipes
and the detector
4.Change the non-metal pipes or
improve the earthing
5.The metal bar or
bracket collides with
the detector
5.Check the hanger or
supporting parts of the
detector
5.Separate the metal bracket and
the detector with spacer to avoid
the collision between the
bracket and the detector
6.The signal emitting
and receiving wires
are
not
properly
connected
or
not
firmly fixed
6.Signal
emitting
and
receiving shielding cable
6.
Fix the signal emitting and
receiving shielding cable in the
corresponding connectors
7.The
metal
hose
threaded with signal
emitting cable is not
fixed and vibrate during
working
7.Signal
emission
and
receiving cable
7. Fix the threaded(wired) metal
hose
8 There is metal
scraps remaining in
the inner cavity of the
detector
or
the
distance between the
detector and vibrating
metal piece is too near
8.Check the inner cavity
and the surroundings of
the detector
8.Remove the sundries inside
the detector and keep a distance
between metal and detector
9. Sensitivity is set too
high.
9. Check the sensitivity
parameter of APU-02
9. Decrease the setting of the
sensitivity
10.
Main
control
panel is damaged
10. Check the main control
panel
10. Repair or change the main
control panel
Table 6: The comparing tale between the troubleshooting of debug process and
normal use