background image

2. In the 60-second interface, it will immediately show the prompt picture 

below. Now you need to simultaneously start your car.

3. If you fail to start your car for the first time, you need to wait for the 30S 

interface for a second attempt. Now you also need to seize the moment and 

simultaneously start your car.

4. If you fail to start your car for the second time, you need to wait until the 

count-down is over and show the prompt picture again for a third attempt.

If you fail to start your car in the three attempts above, the LCD display will 

show as follows. This is the whole working cycle for the "Engine Start" 

function. In this case, if you still want to have a try again, press “Engine 

Start” and “START” buttons again, then repeat previous steps.

PLEASE
START YOUR
ENGINE

Engine Start
PLEASE
WAIT FOR
60 SECS

PLEASE
START YOUR
ENGINE

PLEASE
START YOUR
ENGINE

Engine Start
PLEASE
WAIT FOR
30 SECS

PLEASE 
ENGINE START
BUTTON AGAIN

Engine Start

Содержание BC0253

Страница 1: ...BC0253 Know Batteries Better Smart Battery Charger 12V 2A 10A 25A AUTOMATIC ...

Страница 2: ...even death Electrical Shock The battery charger is an electrical device that may shock and cause serious injury Do not use the charger if the power cords are damaged Do not submerge in water or get wet Explosion Do not attempt to charge any frozen damaged incompatible batteries Never try to charge lithium batteries with high voltage shock Apply the charger only to batteries with recommended voltag...

Страница 3: ... Charging Battery Power PACKAGE OVERVIEW One Ampeak Smart Battery Charger with Battery Clips One Instruction Manual LCD Display Start Pause Charging Rate Selection Battery Type Selection Winter Mode Charging Battery Recondition Battery Desulfation Engine Start Aid Battery Clips 120V AC Plug ...

Страница 4: ...ed on an average discharge depth of 50 to a fully charged battery and is only for reference purposes Actual data may differ due to battery conditions and temperature The charger has 24H Overtime Charging Protection Battery Size Approximate Time To Charge In Hours Ah Amp Hour 2A 10A 25A 25 12 3 2 3 0 75 50 24 5 4 5 1 5 100 200 1000 500 9 0 3 18 0 6 15 30 1V AC 120V 60Hz 9A DC 12V 2A 10A 25A Automat...

Страница 5: ...lip to the negative terminal Plug the battery charger into the 120V AC outlet 2 Select your desired charging rate compatible battery and press START button to start charging All the data will be shown on the LCD screen 3 During the charging you can press Recondition button to check the smart 8 charging stages It will automatically switch back to the main interface in 5 seconds 4 If you would like ...

Страница 6: ...llow your battery to absorb more power 5 Battery Analysis Auto test the battery state after charging Abnormal enter the repair stage Normal turn to the next stage 6 Battery Recondition Restore over discharged batteries After repair return to the Bulk stage If it fails an error will be reported 7 Float Charging Keep battery at 100 without overcharging or damages Leave smart charger 24 7 plugged wit...

Страница 7: ...he initial charging voltage better boosts your battery activity and charges more thoroughly in low temperature situations Battery Recondition With the repair completed you can directly press START button to start charging Or you just wait for about 30 seconds the battery charger will automatically switch to the charging status BATTERY IN REPAIR NOW REPAIR COMPLETED The Recondition function is for ...

Страница 8: ...d to wait Battery Desulfation BATTERY IN DESULFATION NOW DESULFATION COMPLETED With the desulfation completed you can directly press START button to start charging Or you just wait for about 30 seconds the battery charger will automatically switch to the charging status PLEASE START YOUR ENGINE PLEASE START YOUR ENGINE Engine Start PLEASE WAIT FOR 100 SECS The smart battery charger will identify a...

Страница 9: ...eed to wait until the count down is over and show the prompt picture again for a third attempt If you fail to start your car in the three attempts above the LCD display will show as follows This is the whole working cycle for the Engine Start function In this case if you still want to have a try again press Engine Start and START buttons again then repeat previous steps PLEASE START YOUR ENGINE En...

Страница 10: ... be dead check the battery condition Replace battery if needed Correct the polarity to the right connection The temperature of the charger is too high or the internal temperature sensor of the charger fails Make sure the vents are unblocked The charger will recharge automati cally after cooling down If the charger has been unable to restore charging the tempera ture sensor failure by a professiona...

Страница 11: ...y lasts so the above limitations may not apply to you The limited warranty is void under the following conditions Notice All information in this manual is based on the latest information available at the time of publication and no warranty can be made for its accuracy or completeness Ampeak reserves the right to make changes at any time without notice Abnormal charging current Disconnect the AC po...

Отзывы: