Page 121
EVACU ELITE
INSTALLATION, COMMISSIONING AND USER MANUAL
12
Definitions
Activating device
- a device capable of being operated automatically or manually to initiate an alarm
signal, eg. a detector, a manual call point, or a pressure switch.
Alarm system
- facility provided in a building to give an alarm in the event of fire, civil commotion,
bomb threat, leakage of toxic or noxious fumes, structural damage, or other emergency.
Alarm signal
- a signal given by fire alarm, or other alarm system, at the fire indicator panel (FACP)
or other panel to alert wardens and other nominated personnel as necessary to commence prescribed
actions.
Alarm zone
- the specific portion of a building or complex identified by a particular alarm zone facility.
Alert signal
- an audible signal, or combination of audible and visible signals, from the Emergency
warning system to alert wardens and other nominated personnel as necessary to commence
prescribed actions.
Approved and approval
- approved by, or the approval of, the Regulatory Authority concerned.
Control and indicating equipment (CIE)
- a combination of control equipment and indicating
equipment.
Control equipment
- equipment which controls the receipts and transmission of signals within the fire
detection and alarm system or initiates other action.
Emergency alarm initiating device
- a manually operated device by which an alarm is given to
indicate an emergency.
Emergency condition
- is a condition which requires the evacuation of the building or zone.
Emergency control panel (ECP)
- a panel by means of which the emergency warning and
intercommunication system (if any) in the building may be operated [NOTE: see also definition of
master emergency control panel (MECP)].
Emegency intercommunication system (EIS)
- a two-way system which provides voice
communication between the controlling emergency control panel (ECP) and the warden
intercommunication points (WIPS).
Emergency warning and intercommunication system (EWIS)
- a combined emergency warning
and intercommunication system.
Emergency warning system (EWS)
- a system to provide a distinctive audible signal, verbal address,
and visible signals as required, during an emergency condition.
Evacuation sequence
- a pre-programmed sequence initiating alert and evacuation signals to
evacuation zones as required by the Regulations Authority.
Evacuation signal
- an audible signal, or combination of audible signals, from the emergency warning
system to indicate to wardens and building occupants generally that an evacuation or other prescribed
actions are necessary.
Evacuation zone
- a specific portion of a building or complex, in which the evacuation procedures are
managed by one zone warden. [NOTE: this term should not be confused with the concept of 'fire
alarm zone'. Fire alarm zone may or may not cover the same area as an evacuation zone.]
Factory connections
- are connections made during manufacture and should not require any field
alterations.
Field connections
- are connections made to FACP or ancillary equipment at the project during
installation.
Firmware
- the basic operating program which is not intended to be field changeable.
House warden
- a person who, during an emergency, assumes control over the building and its
occupants and is the prime contact with the appropriate emergency services(s).
Interface
- The interconnection between equipment which permits the transfer of data.
Main equipment
- equipment essential to the operation of the system including, control equipment,
amplification equipment and power supply modules.
Master alarm facility (MAF)
- that part of the control and indicating equipment which receives alarm
and fault signals from any alarm zone facility and initiates the common signal (alarm and/or fault) for
transmission to the fire control station where appropriate. Bells and other ancillary functions may be
initiated from this facility.
Содержание EvacU Elite
Страница 1: ...EvacU Elite Emergency Warning Intercom System EWIS Install Commission and User Manual MAN3137 2 ...
Страница 5: ...12 Definitions 121 ...
Страница 78: ...Page 71 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL ...
Страница 80: ...Page 73 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL Figure 7 1 24U Cabinet Front and side view ...
Страница 90: ...Page 83 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL Figure 8 2 MIC wiring standard ...
Страница 91: ...Page 84 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL Figure 8 3 MIC wiring voltage reversal ...
Страница 101: ...Page 94 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL 8 7 1 Field wiring Figure 8 6 150Watt amplifier wiring ...
Страница 104: ...Page 97 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL 8 8 3 Field wiring Figure 8 7 Quad radial EIS wiring ...
Страница 107: ...Page 100 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL Figure 8 8 Dual loop EIS wiring ...
Страница 111: ...Page 104 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL Figure 8 10 Network wiring 2 core copper ...
Страница 112: ...Page 105 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL Figure 8 11 Network wiring Single mode single fibre ...
Страница 113: ...Page 106 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL Figure 8 12 Network wiring Single mode dual fibre ...
Страница 114: ...Page 107 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL Figure 8 13 Network wiring Multi mode dual fibre ...
Страница 115: ...Page 108 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL Figure 8 14 Network wiring Mixed Fibre ...
Страница 116: ...Page 109 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL Figure 8 15 Networking wiring Mixed UTP ...
Страница 119: ...Page 112 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL Figure 8 18 Cable routing left hand side ...
Страница 120: ...Page 113 EVACU ELITE INSTALLATION COMMISSIONING AND USER MANUAL Figure 8 19 Cable routing right hand side ...