background image

271 

A

B

C

D

E

Torque Wrench for Flare Nut

and Pipe Size Expander

Packing

Pipe Size

Expander

Flare Nut

(Connection Pipe)

Screw

Screw

Cabinet side plate

Flare Nut

Torque Wrench for

Flare Nut

(Connection Pipe)

(Connection Pipe)

Applicable to

Liquid and Gas side of

CS-MZ16***, CS-TZ25***,

CS-MTZ16***, CS-TZ35***

CS-Z20***, CS-TZ42***,

CS-Z25***, CS-TZ50***,

CS-Z35***, CS-TE20***,

CS-Z42***, CS-TE25***,

CS-Z50***, CS-TE35***,

CS-XZ20***, CS-TE42***,

CS-XZ25***, CS-TE50***,

CS-XZ35***, CS-E9***,

CS-XZ50***, CS-E12***,

CS-TZ20***, CS-E18***
Liquid side of

CS-Z71***, CS-TZ71***,

CS-TZ60***, CS-TE60***,

CS-E21***

Applicable to

Gas side of
CS-Z71***, CS-TZ71***,

CS-TZ60***, CS-TE60***,

CS-E21***

Torque Wrench for

Flare Nut

Flare Nut

Female side

Male side

Male side

Female side

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Содержание CU-4Z80 Series

Страница 1: ...iping Amin M 2 5 LFL 5 4 h0 2 Amin Required minimum room area in m2 M Required charge amount in appliance in kg LFL Lower flammable limit 0 306 kg m3 h0 Installation height of the appliance 1 8 m for...

Страница 2: ...Unit Installation Diagram 1 Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut 10 mm 2 When installing at roof please consider strong wind and earthquake Please fasten the ins...

Страница 3: ...side of CS MZ16 CS TZ25 CS MTZ16 CS TZ35 CS Z20 CS TZ42 CS Z25 CS TZ50 CS Z35 CS TE20 CS Z42 CS TE25 CS Z50 CS TE35 CS XZ20 CS TE42 CS XZ25 CS TE50 CS XZ35 CS E9 CS XZ50 CS E12 CS TZ20 CS E18 Liquid s...

Страница 4: ...if there is a constant pressure drop Move to next step Step 2 Refrigerant leak detection if there is any pressure drop Otherwise release the Nitrogen gas and move to Step 3 Evacuation of the equipmen...

Страница 5: ...ptor Outdoor unit Liquid side Gas side OPEN Vacuum pump Liquid side 3 way valve Gas side 3 way valve Liquid side Gas side Tube connector Tube connector Tube connector Tube connector Close Close Indoor...

Страница 6: ...s at the interface point are sufficient for the installation of the equipment CU 4Z80 Unit D Unit C Unit A Unit B Indoor Outdoor connection cable Power Supply Cord Isolating Devices Indoor Unit A Indo...

Страница 7: ...remove the burrs 2 Remove the burrs by using reamer If burrs is not removed gas leakage may be caused Turn the piping end down to avoid the metal powder entering the pipe 3 Please make flare after in...

Отзывы: