1
Link Mode:
Determines the bandwidth of the wireless link. CONNEX users can select
High Quality
(40 MHz) or
Stability
Boost
(20 MHz).
NOTE
Note:
CONNEX mini units support High Quality mode only.
2
Frequency Mode:
Determines whether automatic or fixed frequency is used. The options available for fixed frequency
vary according to other options selected (regional settings and Channel Mode).
NOTE
Note:
CONNEX mini units support Auto frequency mode only.
3
Sub-region Settings:
Allows you to set the operating mode of the unit, according to regional regulations. The options are
relevant for European, Chinese, Japanese and Korean regions.
To configure the link:
1.
Make sure that the mobile device on which the CONNEX Management application is installed is
connected to the Air Unit via a USB to Micro USB cable and is connected to the Internet.
2.
Launch the CONNEX Management application, and navigate to the
Link Configuration
screen.
3.
For CONNEX units only:
Select the bandwidth channel mode, as follows:
•
High Quality (40 MHz):
This is the default option which provides the best quality. This is the only
option that can be used with 1080P60 video resolution.
•
Stability Boost (20 MHz):
Use this mode in harsh RF conditions or for long range operations.
This mode enables higher stability, but supports only lower resolutions on the
4.
For CONNEX units only:
Specify the frequency mode by selecting either
Auto
or one of the fixed frequencies listed. The
fixed frequencies that are available vary according to other options selected.
5.
The
Sub-region
options appear for CONNEX and CONNEX mini units used in Europe, Japan, Chi-
na and Korea. (This dropdown menu is hidden when units are used in United States and Australia
regions.) Select options as follows:
• In Europe, select either
Air To Ground
for 5.8 GHz, 25mW or
Indoor
for 5 GHz, 200mW,
Ground use.
• In Japan, select either
Indoor
or
Outdoor
.
Make sure that you select the frequency setting that complies with the local RF regulations in the
region in which you are operating.
6.
To apply the configured changes to the Air Unit, press
Save
.
To return to the out-of-the-box factory settings, press
Restore Defaults
.
NOTE
Note:
A configuration update affects how the Air Unit communicates with
Ground Units with which it is registered [49]
Checking the Ground Units Registered to an Air Unit (Android)
This article explains how to check which Ground Units are paired with a specific Air Unit.