18
OPERATION
Residual temperature indicator
When a hot plate has been switched off, letter “H” is displayed indicating that the hotplate
is still hot.
Do not touch the hotplate and do
not put heat-sensitive objects on
it when the “h” letter is displayed
as you can burn yourself or melt
the object!
When the indication goes out you can touch
the hotplate, bearing in mind that it still does
not have ambient temperature.
Limited time of operation
To increase reliability of the plate each hot-
plate is provided with operation time limiter.
The maximal time of operation depends on
the last selected heating power level.
If the heating power is not changed during the
specified time (see the Table), the hotplate
will be switched off automatically and the
residual temperature indicator will be lighted.
If you want to continue cooking, switch on
the hotplate again at the required level of
heating power.
heating power
level
Maximal time of
operation in hours
1
10
2
5
3
5
4
4
5
3
6
2
7
2
8
2
9
1
During the supply voltage drop
the „h“ is no more shown. In
spite of this the hot fields can be
still hot!
Important! If the cooking plate is
started again after the renewed
switching on or after the supply
voltage drop, a short „self-test”
will be performed. The „h” will
be displayed on the residual
heat indicator during about 45
to 60 minutes. The indication of
residual heat is not based on the
measurement of a value, but on
the calculation depending on the
operating time of hot fields.
After the pause caused by the supply vol-
tage drop the highest possible temperatu-
re and the longest cooling time are taken
into account and therefore the indication
time is so long lasting.
This is of no importance for the further
operation of the cooking plate.
Содержание PB*4VQ247CF
Страница 1: ...PB 4VQ247CF IOAA 646 10 2014 1 OPERATING MANUAL ...
Страница 25: ...25 ...
Страница 26: ...26 ...
Страница 27: ...27 ...
Страница 28: ......