O M EG A F i l t e r s – I n s t a l la t io n & O p e r a t io n M a n u a l
P a g e 3 6 o f 3 6
Maintenance
FLANGE TIGHTENING PROCEDURE:
m. FLANGE TIGHTENING PROCEDURE
:
All flanges in the filter are sealed by O-Rings or GS-ST P/S Gaskets. Therefore it is essential that
load is to be applied gradually and evenly across the Flange to insure even-down and uniform
compression of the Gasket.
Establish a star pattern or cross bolting pattern that will alternate sides of the Flange as load is
applied.
Follow the sequence of numbers according to the relevant pattern.
n. Restarting the filter
1. Double check and verify tightness of all bolts.
2. Clean the working area and remove any unused parts and tools from the Filter Lid.
3. Re-Connect the power and run a "dry flush cycle". Verify opening of the Flushing Valves and proper
motion of the Transmission Gear and Suction Scanners.
4. Close the Drain Valve and open the Inlet Valve to fill the filter with water.
5. Run a few flush cycles while Outlet Valve is still closed.
6. Check and take care of any leaking.
7. Gradually open the Outlet Valve. The filter is now back in operation.
Содержание Omega 13.5K
Страница 2: ......
Страница 5: ...3 Safety Instructions ...
Страница 10: ...4 Technical Specifications ...
Страница 12: ...5 Drawings ...
Страница 18: ......
Страница 19: ...6 Description of Filter Operation ...
Страница 23: ...7 Control Philosophy ...
Страница 31: ...8 Installation Instructions ...
Страница 35: ...9 Commissioning Start up and First Operation ...
Страница 38: ...10 Part Schedule ...
Страница 42: ...OMEGA Filters Installation Operation Manual Page 5 of 9 Part Schedule Main Omega 13 5K 18K Parts Drawing ...
Страница 52: ...11 Maintenance ...
Страница 88: ...12 Troubleshooting ...
Страница 90: ...13 Amiad Limited Warranty ...
Страница 93: ...Appendix A General Arrangement Drawing GA ...