DESCRIPTION OF FILTER OPERATION 

 

Filtering process: 

The SAF-4500 is a sophisticated yet easy-to-operate automatic filter, with a self-cleaning mechanism driven by 
an electric motor. The SAF-4500 is designed to work with various types of screens in filtration degrees from 500 
to 10 micron, and is available in 4", 6" and 8" inlet/outlet diameter. 
The water enters through the inlet pipe into the coarse screen from outside in, and through the fine screen from 
inside out. The "filtration cake" accumulates on the fine screen surface and causes head loss to develop. 
The coarse screen is designed to protect the cleaning mechanism from large dirt particles. It should not 
accumulate large quantities of suspended solids and is not cleaned automatically. 

 
Self-cleaning process:

 

The SAF-4500 will start the self-cleaning process when the pressure differential across the screen reaches a 
pre-set value or a predetermined lapse of time. 
Cleaning of the filter element is carried out by the suction scanner which rotates in a spiral movement while 
removing the filtration cake from the screen and expels it out through the exhaust valve. 
The rotation of the scanner is operated by a 2-way (fwd/rev) drive unit that is attached to the scanner by a 
threaded shaft which provides the linear movement. 
The exhaust valve is activated for the duration of the cleaning cycle by a 3-way solenoid. During the self-
cleaning process, which takes approximately 20 seconds, filtered water continues to flow downstream. 
 

Different modes of filtration:

 

The filtration system may be found in one of the following modes: 
1.  Filtering mode: This is the normal function condition. Flushing is not occurring and the power  light on the 

control board is lit. 

2.  Flushing mode: A mode in which the flushing process is in progress. The motor and exhaust valve are 

operating according to the program. 

3.  Continuous flushing mode: It is possible to activate the self-cleaning mechanism continuously  by changing 

the switch near the timer in the control board to "CONT." position. 

4.  Malfunction mode: During malfunction mode the self-cleaning operation is stopped, the malfunction light on 

the control board is turned on and an external output is activated  with 24V AC. 

 

The filtration system may enter a malfunction mode in the following cases: 

1st.  

When there is a continuous signal from the pressure differential switch for a duration of more than the pre-set time. 
This means that the self-cleaning process is not successful. 

2nd.   When the motor protector was activated, either manually or due to over load. 

3rd.  

As a result of a malfunction in the limit switches.                    

 

Initiation of self-cleaning:

 

The filter will enter the self-cleaning process as a result of any of the following causes: 
 1. A signal from the Pressure Differential Switch (PDS)  - The PDS which is situated on the filter body, sends an electric 

signal when the pressure differential across the screen reaches the pre-set value (usually 0.5 bar =7 psi). The control 
board registers the signal and operates the flushing process according to its program. 

 2. Manually pressing the "TEST" push button at the control board. 
 3. The TIMER installed in the control board allows operation of self-cleaning process at time intervals that can be set up, 

independent from the head loss factor. The timer resets after every flushing cycle. 

 4. A signal from Continual flushing switch  - This switch in the control board allows operation in continuous flushing mode; 

meaning, the filter is flushing itself all the time regardless of flow rate or water quality. 

   

Control system:

 

Two types of control boards are available: PLC Type and Relay Type. See Appendix A or B for details. 

Содержание 2-84

Страница 1: ...tion Operation and Maintenance Instructions Ref 92 9450 5 06 98 amiad filtration systems Serial Number ____________________ Order Number ____________________ Catalogue Number ________________ Filtration Degree __________________ Tested By _______________________ ...

Страница 2: ...ion Drawing 5 Description and Filter Operation 6 Installation 7 Maintenance 8 Disassembling and Reassembling 9 10 Parts Schedule 11 Parts Drawing Section 1 12 Parts Drawing Section 2 13 Control system PLC Type D 14 19 Control system Relay Type C 20 24 With any inquiry please quote Filter Serial Number located on the filter housing ...

Страница 3: ...ater per cycle 83 liter 22 gallon at 2 bar 30 psi Minimum flow for flushing 15 m3 h 66 USgpm at 2 bar 30 psi Control and Electricity Control voltage 24V AC 12V or 24V DC upon request Electric motor 1 3 HP 50 60 Hz 35 42 Gear output R P M Rated operation Voltage 3 phase 220 380 440 V 50 60 Hz Single phase 110 220 V 50 60 Hz DC 12V or 24V upon request Current consumption 0 8 Amp with 3 phase 380 440...

Страница 4: ...as to avoid direct water splashing on the electrical components or on the control panel 7 Extra safety devices should be installed on hot water applications to avoid skin burn danger Operation Control and Maintenance 1 Disconnect the filter from power supply before maintenance or treatment 2 Loosening or unscrewing bolts should be done only after the pressure in the filter had been released 3 Avoi...

Страница 5: ... DRAWING AND RECOMMENDED INSTALLATION Key Dimensions in mm inches 1 6 SAF C 4500 2 6 inlet butterfly valve 3 6 by pass valve option 4 6 downstream valve recommended 5 6 non return check valve option Minimum distance required for maintenance ...

Страница 6: ...rd is lit 2 Flushing mode A mode in which the flushing process is in progress The motor and exhaust valve are operating according to the program 3 Continuous flushing mode It is possible to activate the self cleaning mechanism continuously by changing the switch near the timer in the control board to CONT position 4 Malfunction mode During malfunction mode the self cleaning operation is stopped th...

Страница 7: ... 16 Amp fuse to the L1 L2 L3 inlet at the terminal strip in the control board b b Earth the control board 3 Power connection to the motor Connect the drive unit to the control panel by means of a 4 x 2 5 mm 12 or 14 AWG wire in flex conduct Use a long enough cable to allow removal of the drive unit and placing it near the filter for maintenance without having to disconnect it from the cable It is ...

Страница 8: ...ve the used internal o ring and clean the o ring seat 8 Insert a new o ring 6 9 9 Apply some grease on the external o ring and on the shaft 10 Tighten the sealing nut 6 8 11 Re connect the drive shaft to the suction scanner shaft 12 Operate the control board and open the filter inlet valve Maintenance prior to long term cessation of filter operation The following must be done if the filter will no...

Страница 9: ...bolts seats of the lid should touch the bolts seats of the filter housing 6 Open the filter inlet and outlet valves and operate the control board 7 Check proper operation of the filter Suction scanner Dismantling 1 Begin the dismantling procedure as per 1 4 in the chapter dismantling the fine screen 2 Remove the cover from the drive shaft housing 7 9 by unscrewing the wing nuts 7 11 3 Remove the S...

Страница 10: ... screen 3 Attach the screens adapter seal 6 6 to its place with its flat side using some grease as adhesive material 4 Attach the flushing chamber o ring 4 1 to its place using some grease as adhesive material 5 Apply some grease on the o ring of the upper bearing 6 2 6 Insert the flushing chamber assembly into its place Use the centering pin 4 2 to locate the flange in its position 7 Tighten the ...

Страница 11: ...creen 53 2074 2020 15 1 Connector 5 16 x 1 4 82 13 0682 0504 6 5 Screens Adaptor 13 2071 0020 15 2 Copper Tube 5 16 drain 82 13 0000 0050 6 6 Screens Adapter Seal 81 41 4300 3055 15 3 Connector 1 4 x 1 4 52 0100 0020 6 7 Sealing Nut External O Ring 81 41 4100 0024 16 Solenoid Valve 82 21 0024 0001 6 8 Sealing Nut 53 2074 0001 16 1 L Connector 5 16 x 1 4 82 13 0692 0504 6 9 Sealing Nut Internal O R...

Страница 12: ...12 amiad filtration systems PARTS DRAWING Section 1 ...

Страница 13: ...13 amiad filtration systems PARTS DRAWING Section 2 ...

Страница 14: ...測試 OFF ON 電源開關 電源指示 異常指示 極限指示 排水閥 復歸 馬達指示 時間 差壓 差壓 連續 LG1 LG2 LG3 CS1 LG4 LG5 CS2 PB1 PB2 T1 CT1 14 ...

Страница 15: ...480V 110V 24V 150VA TRANSFORER R2 R1 POWER SOURCE BY CUSTOMER BY CUSTOMER OPTION 15 ...

Страница 16: ...T1 R1 S1 1 4HP 清洗馬達 8 7 W V U 6 5 10A T POWER SOURCE TBM 2 R 1 S NFB 1 3 4 6A NFB 2 4A NFB 3 1 3KW 泵浦 8 7 W2 V2 U2 6 5 16 ...

Страница 17: ...測試 差壓信號 計時器信號 上極限 下極限 清洗馬達過載 時間 連續 異常復歸 REMOTE PAUSE REMOTE RESET 17 ...

Страница 18: ...逆洗完成 計時器 計數器 排水閥 逆洗 過濾 清洗馬達正轉 清洗馬達反轉 DC24V DC24V 異常 極限指示 18 ...

Отзывы: