10
amiad
filtration systems
Drive shaft housing and coarse screen
Dismantling:
1. Close the inlet and outlet valves of the filter and release pressure.
2. Disconnect power supply from the control board.
3. Dismantle the suction scanner and fine screen as described previously.
4. Pull out the plug from the solenoid coil (16).
5. Remove the limit switch sling (10) from the drive shaft housing by unscrewing the bolts (10.1). Carefully
put the limit switch sling near the filter to avoid any damage to the electrical wires.
6. Disconnect the tube (16.3) from the solenoid valve (16) and from connector (19.3).
7. Disconnect the drain pipe from the exhaust valve.
8. Remove the drive shaft cover by unscrewing wing nuts (14.3)
9. Remove the drive unit (12+12.1) from the drive shaft housing (7) by unscrewing the nuts (12.5) from the
bolts (12.2). By doing so the drive shaft key (13) will be pulled out.
10. Dismantle the drive shaft housing (7) from the flushing chamber flange (6) by unscrewing the bolts (7.1).
11. Remove the rest of the flange bolts and pull out the flushing chamber assembly which includes: flushing
camber (6), coarse screen (6.4), screens adapter (6.5) and screens adapter seal (6.6).
Assembly:
1. Place the coarse screen (6.4) in its seat in the flushing chamber.
2. Place the screens adapter (6.5) on the flushing chamber and the coarse screen.
3. Attach the screens adapter seal (6.6) to its place with its flat side, using some grease (as adhesive
material).
4. Attach the flushing chamber o-ring (4.1) to its place using some grease (as adhesive material).
5. Apply some grease on the o-ring of the upper bearing (6.2).
6. Insert the flushing chamber assembly into its place. Use the centering pin (4.2) to locate the flange in its
position.
7. Tighten the flange to the filter housing with the side bolts only (6.10).
8. Apply some grease on the o-rings (6.7 & 6.9) of the shaft sealing nut (6.8) and tighten to its place.
9. Install the drive shaft housing, using the rest of the flange bolts (7.1).
10. Insert the suction scanner (2) and the fine screen (3) as described previously.
11. Connect the drive shaft (8) to the scanner shaft using the connecting pin (8.3) and split pin (8.4).
12. Make sure the drive shaft key (13) is fitted properly in the gear box. Thread the drive shaft through the
drive unit and make sure that the drive shaft groove is adjusted in accordance with the drive shaft key.
13. Connect the drive unit (12+12.1) to the drive shaft housing (7) with the bolts (12.2) and tighten them.
14. Connect the pilot tube between the solenoid valve (16) and the control filter connector (19.3).
15. Assemble the limit switch sling (10) in its place and push in the plug of the solenoid coil.
16. Connect the drain pipe to the exhaust valve (15).
17. Operate the control board and make sure the filter is operating properly.
18. Open the inlet and outlet valves and recheck filter operation.
Содержание 2-84
Страница 12: ...12 amiad filtration systems PARTS DRAWING Section 1 ...
Страница 13: ...13 amiad filtration systems PARTS DRAWING Section 2 ...
Страница 14: ...測試 OFF ON 電源開關 電源指示 異常指示 極限指示 排水閥 復歸 馬達指示 時間 差壓 差壓 連續 LG1 LG2 LG3 CS1 LG4 LG5 CS2 PB1 PB2 T1 CT1 14 ...
Страница 15: ...480V 110V 24V 150VA TRANSFORER R2 R1 POWER SOURCE BY CUSTOMER BY CUSTOMER OPTION 15 ...
Страница 17: ...測試 差壓信號 計時器信號 上極限 下極限 清洗馬達過載 時間 連續 異常復歸 REMOTE PAUSE REMOTE RESET 17 ...
Страница 18: ...逆洗完成 計時器 計數器 排水閥 逆洗 過濾 清洗馬達正轉 清洗馬達反轉 DC24V DC24V 異常 極限指示 18 ...