3
amiad
filtration systems
TECHNICAL SPECIFICATIONS
General
Maximum flow rate
250 m
3
/h
1100 USgpm
Consult manufacturer for optimum
flow depending on filtration degree
& water quality.
Min. working pressure
1.5 bar
21 psi
or lower if pressure is increased
.
for flushing
Max. working pressure
10 bar
150 psi
16 bar = 240 psi upon request
Filter area
4,500 cm
2
700 in
2
Inlet/Outlet diameter
100,150, 200 mm
4", 6", 8"
Flange standards as per request.
Filter housing
250 mm
10"
Epoxy-coated steel, or other on
request.
Max. working temperature
80
0
C
176
0
F
Weight
100 mm = 150 Kg
4" = 330 lb.
150 mm = 156 Kg
6" = 344 lb.
200 mm = 165 Kg
8" = 364 lb.
Flushing Data
Exhaust valve
50 mm
2"
Flushing cycle time
20 seconds
20 seconds
Wasted water per cycle
83 liter
22 gallon
at 2 bar = 30 psi
Minimum flow for flushing
15 m
3
/h
66 USgpm
at 2 bar = 30 psi
Control and Electricity
Control voltage
24V AC
(12V or 24V DC upon request)
Electric motor
1/3 HP
50 / 60 Hz, 35 / 42 Gear output R.P.M.
Rated operation Voltage
3 phase
220 / 380 / 440 V, 50 / 60 Hz
Single phase
110 / 220 V, 50 / 60 Hz
DC
12V or 24V (upon request)
Current consumption
0.8 Amp.
(with 3 phase 380 / 440 V)
Construction Materials
Filter Housing and Lid
Epoxy-coated carbon steel 37-2 (Stainless Steel 316 available on request).
Screens
Stainless Steel 316
Cleaning mechanism
Stainless Steel 316, POM
Exhaust valve
Epoxy-coated cast iron, Natural Rubber
Seals
Synthetic Rubber, Teflon
Control
Aluminum, Brass, Stainless Steel, PVC
Standard Filtration Degrees
Stainless Steel Weavewire Screen
micron
500
300
200
130
100
80
50
25
10
mm
0.5
0.3
0.2
0.13
0.1
0.08
0.05
0.02
0.01
Mesh
30
50
75
120
155
200
300
450
600
Содержание 2-84
Страница 12: ...12 amiad filtration systems PARTS DRAWING Section 1 ...
Страница 13: ...13 amiad filtration systems PARTS DRAWING Section 2 ...
Страница 14: ...測試 OFF ON 電源開關 電源指示 異常指示 極限指示 排水閥 復歸 馬達指示 時間 差壓 差壓 連續 LG1 LG2 LG3 CS1 LG4 LG5 CS2 PB1 PB2 T1 CT1 14 ...
Страница 15: ...480V 110V 24V 150VA TRANSFORER R2 R1 POWER SOURCE BY CUSTOMER BY CUSTOMER OPTION 15 ...
Страница 17: ...測試 差壓信號 計時器信號 上極限 下極限 清洗馬達過載 時間 連續 異常復歸 REMOTE PAUSE REMOTE RESET 17 ...
Страница 18: ...逆洗完成 計時器 計數器 排水閥 逆洗 過濾 清洗馬達正轉 清洗馬達反轉 DC24V DC24V 異常 極限指示 18 ...