Certificate:
1905645
Project:
70159520
Master Contract:
227773
Date Issued:
November 28, 2017
DQD 507 Rev. 2016-02-18
Page 2
APPLICABLE REQUIREMENTS
CSA C22.2 No 0-10
General Requirements – Canadian Electrical Code, Part II – Tenth
Edition
CSA C22.2 No 30-M1986
(R 2007)
Explosion-Proof Enclosures for Use in Class I Hazardous Locations
Industrial Products – Third Edition
CSA C22.2 No 142-M1987
(R
2009)
Process Control Equipment Industrial Products – Third Edition
CSA C22.2 No 157-92
(R 2006)
Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous
Locations – Third Edition
UL 913
Intrinsically Safe Apparatus and Associated Apparatus for Use in Class
I, II, and III, Division 1, Hazardous (Classified) Locations - Seventh
Edition
UL 916
Energy Management Equipment – Fourth Edition
UL 1203
Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use
in Hazardous (Classified) Locations – Fourth Edition
MARKINGS
The manufacturer is required to apply the following markings:
•
Products shall be marked with the markings specified by the particular product standard.
•
Products certified for Canada shall have all Caution and Warning markings in both English and French.
Additional bilingual markings not covered by the product standard(s) may be required by the Authorities Having
Jurisdiction. It is the responsibility of the manufacturer to provide and apply these additional markings, where
applicable, in accordance with the requirements of those authorities.
The products listed are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and
US (indicating that products have been manufactured to the requirements of both Canadian and U.S. Standards) or
with adjacent indicator 'US' for US only or without either indicator for Canada only.
The following markings are permanently embossed, die-stamped or etched on a metallic nameplate, have a
minimum thickness of 0.5mm, which is secured to flow-meter enclosure by two screws.
•
Manufacturer’s name: "Advanced Micro Instruments", or CSA Master Contract Number “227773”, adjacent to
the CSA Mark in lieu of manufacturer’s name.
•
Model number: As specified in the PRODUCTS section, above.
•
Electrical ratings: As specified in the PRODUCTS section, above.
•
Relay contacts rating: As specified in the PRODUCTS section, above.
•
Manufacturing date in MMYY format, or serial number, traceable to month of manufacture.
•
The CSA Mark with or without “C” and “US” indicators, as shown on the Certificate of Conformity.
•
Hazardous Location designation: As specified in the PRODUCTS section, above (may be abbreviated).
•
Temperature code: As specified in the PRODUCTS section, above.
•
The following words:
o
Caution: “Warning – Explosion Hazard – Keep explosion-proof cover tight while circuits are alive.
Substitution of components may impair intrinsic safety”
Содержание 210BR
Страница 1: ...08 31 2018 Made in the USA AMI Oxygen Analyzer Manual Model 210BR Costa Mesa CA ...
Страница 2: ...AMI Analyzer Manual Contents i ...
Страница 16: ...AMI Analyzer Manual Installation Procedure 13 ...
Страница 24: ...AMI Analyzer Manual Analyzer Description 21 Drawings Figure 7 Outline Drawing Figure 8 Flow schematic ...
Страница 25: ...AMI Analyzer Manual Analyzer Description 22 Figure 9 Control drawing AC unit Figure 10 Control drawing DC unit ...