36
Counterclockwise to increase
the down speed
4. Adjust the lower speed
You can adjust the lower speed of the lift if needing: then turn the throttle valve
clockwise to decrease the lower speed, or counterclockwise to increase the lower
speed.
5. Test with load
After finishing the above adjustment, test running the lift with load. Run the lift in low
position for several times first, make sure the lift can rise and lower synchronously,
the safety device can lock and release synchronously. And then test run the lift to the
top completely. If there are anything improper, repeat the above adjustment.
NOTE: It may be vibrated when lifting at start, lifting it with load for several times,
the air would be bled and the vibration would be disappeared automatically.
Clockwise to decrease the
down speed
Throttle Valve
Fig. 47
Throttle Valve
Fig. 48
Hydraulic Schematic Diagram
Содержание OH-12
Страница 1: ...Two Post Lift Model OH 12 Original...
Страница 4: ...2 Arm Swings View Fig 2 3829mm 2787mm 109 3 4 150 3 4...
Страница 17: ...15 K Lift the carriages up by hand and make them be locked at the same level See Fig 26 Fig 26...
Страница 19: ...17 1 2 Connecting cable for high setting See Fig 28 High Setting Cable 1 Cable 2 Fig 28 Cable 1...
Страница 27: ...25 L1 Motor Power Line 3 4 3 4 A1 Remove this wire before connecting the Limit Switch Fig 39 Fig 38 N 11 12 L...
Страница 28: ...26 IV EXPLODED VIEW Model OH 12 Fig 40...
Страница 34: ...32 4 3 Manual Power unit 071102 220V 60HZ Single Phase Fig 43...