13
I. Installing the limit control bar and limit switch
(See Fig. 23).
Fig.
23
60
Loosen Screw
of Drive Rod for
adjustment,
Tighten the
screw after
adjustment
Limit Switch
is connected with Cable
Connect the brown wire to
terminal 12# of limit switch
and terminal L1 of AC
Connect the blue wire to terminal
11# of limit switch and terminal
4# of power unit.
Connect the yellow and green
wire to the terminal earth wire
of limit switch and terminal
earth wire of power
NC: Normal contact
97
96
98
1
23
99
21
22
61
59
52