A6 Quick Start: Hart
CAUTION
Copyright
©
2016 A & H Enterprises, Inc.
All rights reserved
00000329-0900-014 * Rev. B, 06/16
Page 17 of 21
AMFLOW
®
Caution
VALVE INSTALLATION
RECOMMENDATION
The purge port on an
Amflow
®
valve should be connected to a “return to
tank line” with a needle valve. This aids in the following:
Helps remove air from valve upon start-up.
Provides a means of cleaning jets with high pressure in the event of
chemical build-up.
IMPORTANT
Proper filtration is critical for low flow applications.
RECOMMENDATION:
50 micron filter
VALVE START-UP
Step 1
Turn adjustment knob counter-clockwise to a soft
“Stop”.
Then, turn one (1) revolution clock-wise.
Step 2
Close Inlet Isolation valve of
each valve in system
Step 3
Start pump
Adjust system pressure to accommodate pressure requirements
CAUTION
IMPROPER INSTALLATION AND START-UP MAY CAUSE DAMAGE
IMPORTANT
This is especially important for valves configured to flow less than 5 lph