SI5500 User Manual 503147 

Issue 5 

28 of 53 

 

 

8.7 PRESET/LIMITS  MENU 

 

 

 
 
 

OPTIONS

Preset/Limits Menu

 

Channel Nr

 

 

Preset

 

 

 

Upper Limit

 

 

 

Lower Limit

 

 

 

                         Exit Menu

 

C1, C2, C3, ……., C31
 

 

+000.00000

 

 

 

+003.00000

 

 

 

-003.00000

 

  

 

 

 

 

 

 

 

 

 

Содержание si 5000

Страница 1: ......

Страница 2: ...express permission of Solartron Metrology 2012 Solartron Metrology Ltd All rights reserved Microsoft Windows XP Windows Vista Windows 7 Excel VBA and VB are registered trademarks or trademarks of Mic...

Страница 3: ...RMATION 8 5 1 TERMS ASSOCIATED WITH SI5500 Read out 8 6 ELECTRICAL INSTALLATION 10 7 DISPLAY AND KEYPAD 11 7 1 OPERATE SCREEN 11 7 2 Switching to the single channel configuration for the selected chan...

Страница 4: ...enu 28 8 8 Input Output Menu 29 8 8 1 Pin Details of Discrete Outputs 30 8 8 2 Pin Details of Discrete Inputs 30 8 9 PRINT Options 32 8 9 1 PRINT FORMAT 35 8 10 Serial Port Menu 38 8 11 Advanced Measu...

Страница 5: ...SI5500 User Manual 503147 Issue 5 5 of 53 10 SERIAL COMMANDS 49 11 MEASUREMENT AND TIMING INFORMATION 52 12 RETURN OF GOODS 53...

Страница 6: ...efined formulas expressions for each of the measurement channel A maximum of 31 measurement channels are supported The read out can be configured through a 9 button keypad 3x3 Basic Input Output is pr...

Страница 7: ...not operate in an explosive atmosphere Warning this equipment is not intended for safety critical applications Warning Do not operate without covers Warning do not exceed maximum ratings as specified...

Страница 8: ...ertain parameters functionalities Discrete Outputs Digital lines output from read out that can be used to drive external loads These can be with either NPN or PNP configuration Serial Interface This i...

Страница 9: ...es are not affected When zeroing all channels Zero Preset All ON the probes and measurement results are both zeroed eg Probes a b c and computed measurement C1 C2 C3 For formuale containing Mx and Mn...

Страница 10: ...Probes of up to 31 sensors can be connected together SI5500 read out supports interface of DP probes Spring Push Pneumatic Linear Encoders and Encoder Input Modules RS232 COMM Connector Refer to RS23...

Страница 11: ...can select the required type of display through Display Configuration Menu In the multi channel configuration user can scroll through the required set of channels using and arrow keys The scrolling i...

Страница 12: ...The blue cursor on top of the bar indicates the current selected channel The resolution of max min range values is limited to 3 decimal points only due to constraint in the available display area Use...

Страница 13: ...channel readings in bar mode The blue cursor on top of the bar indicates the current selected channel NOTE that in this mode the readings and no other information related to the measurement channel i...

Страница 14: ...configuration This mode displays the 8 consecutive channel readings in text mode The blue cursor on left of the channel reading indicates the selected channel User can switch to Single Channel Configu...

Страница 15: ...Configuration This mode displays the 16 consecutive channel readings in text mode The blue cursor on left of the channel reading indicates the selected channel User can switch to Single Channel Config...

Страница 16: ...is error occurs when one or more Linear Sensors used in the formula for the corresponding channel reports OverSpeed Error When this error occurs the bar is drawn with full scale in RED color To reset...

Страница 17: ...than 1 second will perform PEAK RESET on all the channels PRINT Key Prints the reading according to the mode selected Refer to the PRINT Options section for information on PRINT options configuration...

Страница 18: ...does not work in STATIC mode ZERO and PEAK TRACK key functions similar to that of Single Channel Configuration To exit STATIC mode use PEAK TRACK key Search option is used to display the channel chan...

Страница 19: ...through Autosense Mode menu screen When a channel is within limits it is displayed in Single Channel Configuration mode If none of the channel is within limits then the status message Probes Parked m...

Страница 20: ...Formula Edit Menu Screen Will erase the complete formula so that the user can enter the required formula from the beginning PEAK TRACK Key Used only in Formula Edit Menu Screen Acts as a backspace key...

Страница 21: ...e saved and used further 8 1SETUP MENU The main SetUp Menu has two pages Page1 and Page2 ENTER SetUp Menu Page 1 ENTER Display Configuration Probes Computed Measurement Measurement Mode Preset Limits...

Страница 22: ...ing is changed only in multiples of the configured Last Digit Step configuration setting For e g If the setting is set to 2 and the reading changes from 7 5264 to 7 5267 the reading on the display is...

Страница 23: ...ols the units of measure scaling for the types of input shown eg converting mm to inches The settings in this menu affect available units thoughout the system see section 8 5 for more details OPTIONS...

Страница 24: ...e tip it takes about 500ms to update the data on the display Resolution can be changed only for DP type probes It is also not possible to change if a sensor is in Difference Mode Difference mode is st...

Страница 25: ...AXA mm inch mils deg V mV A mA degC degF bar hPa MPa kPA mg Kg rpm Auto Unipolar Bipolar 000 000000 ENTER Key to edit the formula Use and arrow keys to move through the formula string ZERO key will er...

Страница 26: ...to erase the current pop up and the new pop up window will be displayed For eg If user is in Opd pop up window display and wants to open Math pop up window it is not necessary to scroll through all t...

Страница 27: ...for the configured trigger time period In PEAK mode peak value is reset to the current reading if it goes above the configured trigger level for the configured trigger time period Measurement Mode Men...

Страница 28: ...SI5500 User Manual 503147 Issue 5 28 of 53 8 7PRESET LIMITS MENU OPTIONS Preset Limits Menu Channel Nr Preset Upper Limit Lower Limit Exit Menu C1 C2 C3 C31 000 00000 003 00000 003 00000...

Страница 29: ...nc Back Next Menu Active LOW Active HIGH C1 C2 C3 C31 OK Under Over None C1 C2 C3 C31 OK Under Over None C1 C2 C3 C31 OK Under Over None C1 C2 C3 C31 OK Under Over None Input Output Page 2 Out5 ChNr F...

Страница 30: ...screte Outputs PIN No Description 1 Out1 14 Out2 2 Out3 15 Out4 3 Out5 16 Out6 4 Isolated O P Common In Gauging mode Out1 2 3 will perform as shown below Output Description Out1 Asserted if any channe...

Страница 31: ...ream of data onto RS232 port PRINT For Edge Input type It sends single PRINT data onto RS232 port For ACTIVE Input It sends continual PRINT stream of data onto RS232 port 6 LOG Starts data logging LEF...

Страница 32: ...ser Manual 503147 Issue 5 32 of 53 8 9PRINT OPTIONS PIN 20 PINS 17 5 18 6 19 7 Load up to 500mA PIN 4 PINS 1 14 2 15 3 16 GND External Supply 10V to 24V DC Discrete Outputs Schematic Discrete Inputs S...

Страница 33: ...C mode i e Scan option is selected through Gauging Mode result Screen current displayed channel reading is printed Prints Current Reading of the displayed channel within limits If there is no channel...

Страница 34: ...annel If in STATIC each PRINT will advance to the next channel and prints the reading After the last channel selected for scan is printed the display reverts back to the first channel All Readings Pri...

Страница 35: ...x x x r a d Below Lower Limit x x x x x Within limits x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x C 1 1 3 4 8 1...

Страница 36: ...x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x...

Страница 37: ...Space Sign Carriage return Line Feed P n t x x r n P n t x x x x x x x x x x x x x x x x x x x x x x P n t 1 7 4 9 8 2 r n P n t 2 1 0 6 2 9 0 r n P n t 3 9 1 8 6 3 r n Reading Nr PEAK Reading Eg PEA...

Страница 38: ...7 3 7 1 6 r n R a n g e 0 1 2 6 6 r n A v e r a g e 7 3 9 1 5 r n Result value Eg Max 7 4982 Min 7 3716 Range 0 1266 and Average 7 3915 Result Type 8 10 SERIAL PORT MENU Pin diagram of RS232 port OPT...

Страница 39: ...SI5500 User Manual 503147 Issue 5 39 of 53 PIN Description 1 Not Used 2 RS232 Tx 3 RS232 Rx 4 Not Used 5 RS232 GND 6 Not Used 7 Not Used 8 Not Used 9 Not Used 8 11 ADVANCED MEASUREMENT MODE MENU...

Страница 40: ...o of Channels Search Delay Exit Menu OPTIONS Autosense mode selected OPTIONS Gauging mode selected Advanced Measurement Mode Menu Advanced Mode Exit Menu None Gauging Autosense PEAK mode Advanced Meas...

Страница 41: ...number of PEAK readings is input the unit enters into analysis phase and the readings are analyzed and below mentioned calculated result values are displayed through a result message pop up window Ma...

Страница 42: ...id password authentication is required for any key press Password Settings Menu Utilities Menu Restore Factory Settings Password Settings Logging Settings Screen Settings About Exit Menu This option r...

Страница 43: ...up to 8 sets of data onto OPTIONS Opens a pop up window to choose the Log Page Logging Settings Page 1 Mode Interval ms Duration ms Channel Count Back Next Menu OPTIONS Standard Start on I P Trig on I...

Страница 44: ...ption in this mode Logging can be stopped through Stop Logging menu option or it is switched OFF after the configured duration time is elapsed in this mode Refer to Pin Details of Discrete Inputs sect...

Страница 45: ...ng can be adjusted with the provided contrast levels options 8 12 3 ABOUT About Menu screen display firmware version of both MICRO1 and MICRO2 It is displayed in the format MICRO1 Ver MICRO2 Ver SI550...

Страница 46: ...en will be displayed with an on screen tip In the NOTIFY screen NOTIFY option will no longer be available instead Cancel option will be available The probe tip should be moved in such a way that the r...

Страница 47: ...ils of discrete inputs This step will clear all the previously tracked PEAK or PEAK or run out values NOTE It takes 0 5sec to perform a PEAK reset on the probe if it is configured in Difference mode f...

Страница 48: ...tting through Display Configuration Menu to perform ZERO operation on all the channels at once Instead of ZERO operation PRESET operation can be performed according to the user requirements Press UP a...

Страница 49: ...n ascii string from 0 to 30 Pad with 0x20 space character to make the command 13 characters long including the S characters Eg To Zero channel 0 S Z 0 pad with 9 spaces to 13 characters To Preset chan...

Страница 50: ...ces after DP setting in Display Configuration menu Mode User defined formula Upto 100 chars Limits Channel Nr C1 to C31 Reading Right aligned with DP set throgh Places after DP setting in Display Conf...

Страница 51: ...x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x C 1 1 3 4 8 1 5 i n c h r n Eg For channel C1 with reading as 1 34...

Страница 52: ...t channels are used or less trigonometric functions are used then the update rate can be faster can become less than 30ms Response to digital input Within 100ms from the time of setting the input Digi...

Страница 53: ...andard assessment charge is applicable on all non warranty devices returned for repair Customer damage and any device found upon inspection to have no fault will be considered non warranty Please cont...

Отзывы: