![Ametek SHPF3 Series Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/ametek/shpf3-series/shpf3-series_instruction-operation-and-maintenance-manual_2931249023.webp)
SHPF3 SCR Power Controller
Option
Setup
Rev 2
Ametek HDR Power Systems
17
CHAPTER 5 – Options Setup
5.1
Option OC (Overcurrent Trip)
Refer to Chapter 4, and review the setup procedure for the ZERO and SPAN controls. Then adjust
Option OC as follows:
a. Adjust the OC
(CUR/PWR)
potentiometer fully CW.
b. Adjust
ZERO
and
SPAN
as previously described in Chapter 4.
c. With the power controller at full output, adjust OC (CUR/PWR) potentiometer CCW until the unit
shuts off.
d. Adjust the OC
(CUR/PWR)
potentiometer slightly CW.
e. Momentarily press the RESET pushbutton on the Current Limit option PCB on the inside front
door. The power controller should turn on.
5.2
Option CL/OC (Current Limit/Over Current Trip)
Refer to Chapter 4, and review the setup procedure for the ZERO and SPAN controls. Then adjust
Option CL as follows:
a. Set the TRIP LEVEL potentiometer fully CW.
Figure 5.1 Current Limit/Trip Board
b. Adjust the CURRENT LIMIT
(CUR/PWR)
potentiometer fully CW.
c. Adjust ZERO and SPAN as previously described.
d. Adjust CURRENT LIMIT
(CUR/PWR)
potentiometer full CCW.
e. Increase the input control signal to demand full output
f. Adjust the CURRENT LIMIT
(CUR/PWR)
potentiometer until maximum current level is reached.
g. With the power controller at full output, adjust the TRIP LEVEL potentiometer CCW until the unit
shuts off.
Trip Level Potentiometer
Содержание SHPF3 Series
Страница 6: ...Table of Contents SHPF3 SCR Power Controller iv Ametek HDR Power Systems Rev 2...
Страница 8: ...Safety Instructions SHPF3 SCR Power Controller 2 Ametek HDR Power Systems Rev 2...
Страница 22: ...Operation SHPF3 SCR Power Controller 16 Ametek HDR Power Systems Rev 2...
Страница 36: ...Appendix SHPF3 SCR Power Controller 30 Ametek HDR Power Systems Rev 2 Appendix B 15 and 25 A Outline R...
Страница 37: ...SHPF3 SCR Power Controller Appendix Rev 2 Ametek HDR Power Systems 31 Appendix C 60 225 A Outline R...
Страница 39: ...Notes...
Страница 40: ...503 Lakeview Plaza Blvd Ste C Worthington Ohio 43085 USA...