February 2, 2011 Revised 7-4
193111-047
Programming Your SCR2000 Control
45. REFRESH The number of hours before the
DELAY charger automatically starts and
refresh charges a battery that has
not been disconnected
(8 to 99 hrs).
Factory setting = 72 hours
Key in data and press enter.
46. TERM TYPE Disables the automatic DV/DT
charge termination feature and
enables Voltage Time charge
termination
0 = (DV/DT mode) factory
setting
1 = ON (VT mode)
Key in data and press enter.
47. MONTH The current month (1 to 12).
Key in data and press enter.
48. DATE The current day of the month
(1 to 31).
Key in data and press enter.
49. YEAR The current year (00 to 99).
Key in data and press enter.
50. COOL DOWN The number of hours cool down
HRS from the end of charge until charge
complete is indicated by the
charger (0 to 8).
0 = factory setting
Key in data and press enter.
BID Programming
The following conditions must be met before a BID can
be programmed with this control:
a. A battery with the correct cell size BID must be
connected to the charger.
b. The control must be in the Manual Stop condition.
c. The control must be set to the programming menu
and functions 52 thru 55 or 58 must be selected.
After the above conditions are met, the BID can be
properly programmed. After a number entry is keyed in,
the control will immediately attempt to program it in the
BID while displaying READ BID. If the entered number
is out of range or is not accepted by the BID, the control
will return to the original prompt with all 0’s displayed for
the entered data. If the BID properly accepts the data,
the programmed number will be returned to the display.
51. EXTRA RUN The programmed run time after
TIME normal charge complete.
(0 to 60 minutes)
Factory setting = 00
52. PRG.BID CELLS Programs the Cell Size into
the BID.
06 = 6 Cells
09 = 9 Cells
12 = 12 Cells
18 = 18 Cells
24 = 24 Cells
36 = 36 Cells
40 = 40 Cells
53. PROG. BID NO. Programs the battery
identification number into the
BID.
(000000 to 999999)
54. PROG. BID A.H. Programs the battery ampere
hour rating into the BID.
(0000 to 9999)
55. PROG BATT. Programs the battery type
TYPE into the BID.
00 FLD Flooded Lead Acid
01 CTM Custom Curve
(programmable)
02 YGR Sealed battery
curve
03 SLR Sealed battery
curve
04 DSG Sealed battery
curve
(Deka Dominator)
05 SLE Sealed battery
Curve
08 MAX Opportunity Charge
curve
56. NO GASSING The number of hours before
HOURS the charger can begin the
gassing portion of the
charging cycle. (0-8 hours)
Factory setting = 00 hours
Use the up or down arrow
to select the proper setting.