background image

A01-00159 Rev B

 

 

25

 

 

 

 

 

 

 

 

 

19: Acceptable input voltage range setting 

Interface 

Setting 

 

 

 

 

Parameter 2: 

Set the acceptable high 

voltage point and acceptable low voltage 

point for input voltage range by pressing the 

Down key or Up key. 

HLS: 

Input high voltage point 

2. (Default: 300Vac) 

For 100/110/115/120/127 VAC models: 

140/145/150: 

setting the high voltage point in 

parameter 2. (Default: 150Vac) 

LLS: 

Bypass low voltage point 

For 

110/120/130/140/150/160: 

setting the 

low voltage point in parameter 2. (Default: 

110Vac) 

For 100/110/115/120/127 VAC models: 

55/60/65/70/75/80: 

setting the low voltage 

point in parameter 2. (Default: 55Vac) 

 

00: Exit setting 

Interface 

Setting 

 

 

 

 

Exit the setting mode. 

 

 

 

Содержание Powervar Sinergy III 2kVA

Страница 1: ...Sinergy III UPS Tower User s Manual 2kVA 3kVA...

Страница 2: ...AND SETUP 10 2 1 Rear Panel View 10 2 2 Operating Principle 11 2 3 Setup the UPS 11 3 0 OPERATIONS 15 3 1 Button Operation 15 3 2 LCD Panel 16 3 3 Audible Alarm 17 3 4 LCD Display Wordings Index 18 3...

Страница 3: ...les and distribution offices in United Kingdom Germany Canada and Mexico The company s primary products include transformer based power conditioners and uninterruptible power supplies UPS It is ISO 90...

Страница 4: ...operator injury and orequipment damage Other warning symbols may appear along with the Danger and Caution symbol and are used to specify special hazards Thesewarnings describe particular areas where...

Страница 5: ...lutely dry before being installed Please allow at least two hours for the UPS system to acclimate the environment Do not install the UPS system near water or in moist environments Do not install the U...

Страница 6: ...r use in amaximum ambient of 40 C 104 F For Pluggable Equipment The socket outlet shall be installednear the equipment and shall be easily accessible 1 4 Operation Do not disconnect the mains cable on...

Страница 7: ...persons are adequately familiar with batteries and with therequired precautionary measures may replace batteries and supervise operations Unauthorized persons must be kept well away from the batterie...

Страница 8: ...rounded When changing batteries install the same number and same type of batteries or battery packs For UPS with internally mounted battery Instructions shall carry sufficient information to enable th...

Страница 9: ...ction against harmful interference when the equipment is operated in a commercialenvironment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor...

Страница 10: ...e in a safe place for future use 2 1 Rear panel view Tower Models NEMA Type 2K 3K 1 Programmable outlets connect to non critical loads 2 Output receptacles connect to mission critical loads 3 AC input...

Страница 11: ...oper location to install UPS 1 UPS should be placed on the flat and clean surface Place it in an area away from vibration dust humidity high temperature flammable liquids gases corrosive and conductiv...

Страница 12: ...nance Step 1 UPS input connection Plug the UPS into a two pole three wire grounded receptacle only Avoid using extension cords For 100 110 115 120 127VAC models The power cord is attachedto the UPS Th...

Страница 13: ...wn start up and status monitoring connect the communication cable one end to the USB RS 232 port and the other to the communication port of your PC With the monitoring software installed you can sched...

Страница 14: ...l plate will beremoved NOTE The EPO function logic can be set up via LCD setting Pleaserefer to program 16 in UPS setting for the details Step 6 Turn on the UPS Press the ON Mute button on the front p...

Страница 15: ...firm selection key Press this button to confirm selection in UPS setting mode Select Button Switch LCD message Press this button to change the LCDmessage for input voltage input frequency input curren...

Страница 16: ...the codes are listed in detail in section 3 7 and 3 8 Mute operation Indicates that the UPS alarm is disabled Input Battery Temperature Output Load information Indicate the input voltage input frequen...

Страница 17: ...s enabled Indicates the AC to DC circuit is working Indicates the PFC circuit is working Indicates the inverter circuit is working Indicates the UPS is working in converter mode Indicates the output i...

Страница 18: ...ape HLS High loss LLS Low loss AO Active open AC Active close EAT Estimated autonomy time RAT Running autonomy time SD Shutdown OK OK ON ON BL Battery Low OL Over Load OI Over input current NC Battery...

Страница 19: ...ace Setting Parameter 2 Output voltage For 100 110 115 120 127 VAC models you may choose the following output voltage 100 presents output voltage is 100Vac 110 presents output voltage is 110Vac 115 pr...

Страница 20: ...ameter 2 Enable or disable ECO function You may choose the following two options ENA ECO mode enable DIS ECO mode disable Default 05 ECO voltage range setting Interface Setting Parameter 2 Set the acc...

Страница 21: ...27 VAC models 85 115 setting the low voltage point in parameter 3 from 85Vac to 115Vac Default 85Vac 08 Bypass frequency range setting Interface Setting Parameter 2 Set the acceptable high frequency p...

Страница 22: ...es on battery mode Default 999 11 Autonomy limitation setting Interface Setting Parameter 2 Set up backup time on battery mode for general outlets 0 999 setting the backup time in minutes from 0 999 f...

Страница 23: ...and high voltage model with 72 96VDC 1 2 4 6 8 setting the charger maximum current 1 2 4 6 8 in Ampere Default 2A Note Please set the appropriate charger current based on battery capacity used The re...

Страница 24: ...PO logic it will activate EPO function with Pin 1 and Pin 2 in close status 17 External output isolation transformer connection Interface Setting Parameter 2 Allow or disallow external output isolatio...

Страница 25: ...high voltage point 2 Default 300Vac For 100 110 115 120 127 VAC models 140 145 150 setting the high voltage point in parameter 2 Default 150Vac LLS Bypass low voltage point For 110 120 130 140 150 16...

Страница 26: ...input frequency is within 40 Hz to 70 Hz the UPS can be set ata constant output frequency 50 Hzor 60 Hz The UPS will still charge battery under this mode Battery mode When the input voltage is beyond...

Страница 27: ...3 Inverter voltage Low 13 x Charger failure 45 x Inverter output short 14 x Over input current 49 x 3 8 Warning indicator Warning Icon flashing Code Alarm Low Battery Sounding every 2 seconds Overload...

Страница 28: ...something wrong with battery Out of bypass voltage range Sounding every 2 seconds Bypass frequency unstable Sounding every 2 seconds Battery replacement Sounding every 2 seconds EEPROM error Sounding...

Страница 29: ...closed position to disable EPO function The icons of and and the warning code flash on LCD display Alarm is sounding every 2 seconds Line and neutral conductors of UPS input are reversed Rotate mains...

Страница 30: ...PS is over input current Remove excess loads from UPS output Fault code is shown as 43 and the icon is lighting on LCD display Alarm is continuously sounding The UPS shut down automatically because of...

Страница 31: ...ort Batteries defect Contact your dealer to replace the battery Fault code is shown as2A on LCD display andalarm is continuously sounding The short circuit occurs on the charger output Check if batter...

Страница 32: ...your dealer Be sure to deliver the spent battery to a recycling facility or ship it to your dealer in the replacement battery packing material Storage Before storing charge the UPS 5 hours Store the...

Страница 33: ...5 or 87VAC 77VAC 67VAC 62VAC 5 High Line Transfer 150 VAC 5 High Line Comeback 145 VAC 5 Frequency Range 40Hz 70 Hz Phase Single phase with ground Power Factor 0 95 full load THDi 5 100 130VAC THDU 1...

Страница 34: ...Net Weight kgs With battery 23 2 28 0 Without battery 9 9 12 3 ENVIRONMENT Operation Humidity 20 95 RH 0 40 C non condensing Noise Level Less than 50dBA 1 Meter With fan speed control MANAGEMENT Smart...

Страница 35: ...0Hz 1 2000VA 1930W 127Vac input 2000VA 1930W 125Vac input 2000VA 1850W 120Vac input 2000VA 1740W 115Vac input 2000VA 1640W 110Vac input 2000VA 1500W 100Vac input 3K 110 127Vac 50 60Hz 24A 1 100 110 11...

Страница 36: ...ies expressed or implied of merchantability fitness for a particular purpose performance condition capacity or otherwise AMETEK Powervar is not liable for incidental or consequential damages monetary...

Страница 37: ...A01 00159 Rev B 37...

Страница 38: ...ct information and support on the web at www powervar com A01 00159 Rev B 06 2021 2021 AMETEK Powervar Inc Europe Asia Address Unit 5 Birch Kembrey Park Swindon Wilts SN2 8UU UK P 44 1793 553980 F 44...

Отзывы: