Chapter 4: Application Examples
Installation & Programming Manual
20
0016
IF CONFIGURATION IS COMPLETE AND THERE ARE NO RESOLVER 2 FAULTS, COPY RESOLVER 2
POSITION TO A NON-VOLATILE LOCATION AND SET FLAG INDICATING VALID RESOLVER 2 POSITION
Bit Set
N10:0
Open Res 2
I:1
6
3
OTHER
Short Res 2
I:1
2
OTHER
COP
Copy File
Source #I:1.5
Dest #N9:13
Length
2
Set Res 2 Valid
Pos Bit
B3:0
( L )
14
Complete NO Primary
NO Primary
Config
Res 2
I:1
1
OTHER
NO S1Open
Res 2
I:1
0
OTHER
NO S4 Open
IF CONFIGURATION IS COMPLETE AND THERE IS A RESOLVER 1 FAULT, CLEAR THE FLAG TO
INDICATE RESOLVER 1 POSITION IS INVALID
Bit Set
N10:0
Error for Res 1
I:1
6
7
OTHER
Complete
Primary Open
Config
0017
Valid Pos Bit
B3:0
( U )
15
Clear Res 1
Error Res 1
I:1
6
OTHER
Primary Short
Error Res 1
I:1
5
OTHER
S1 Open
Error Res 1
I:1
4
OTHER
S4 Open