5.4 Motor specification

BG65Sx25 MI

Nominal voltage

24 V

Nominal power

 176 W

Nominal torque

41,6 Ncm 

2)

Recommended  

speed control range

100 min

-1

 ...  

Nominal speed

Nominal speed

3065 rpm

Maximal permitted  

continuous current

7,3 A 

Maximum peak current 

per motor phase

19 A (for 75 sec. @20°C)

Nominal voltage

40 V

Nominal power

187 W

Nominal torque

45,7 Ncm 

2)

Recommended  

speed control range

100 min

-1

 ...  

Nominal speed

Nominal speed

3220 rpm

Maximal permitted  

continuous current

4,6 A

Maximum peak current 

per motor phase

12 A (for 77 sec. @20°C)

2)

 The nominal torque depends on how the motor is

cooled. For this reason, the nominal torque is 

measured according to VDE/EN.

Values   for different operating voltages can be found in 

corresponding specifications. These are available on 

request.

5.4 Motorspezifikationen

BG65Sx25 MI

Nennspannung   

24 V

Nennleistung  

 176 W

Nenndrehmoment

41,6 Ncm 

2)

empfohlener 

Drehzahlregelbereich

100 min

-1

 ...  

Nenndrehzahl

Nenndrehzahl

3065 U/min

Maximal zulässiger 

 

Dauerstrom

7,3 A 

Max. Spitzenstrom in der

Motorphase

19 A (für 75 sec. @20°C)

Nennspannung   

40 V

Nennleistung  

187 W

Nenndrehmoment

45,7 Ncm 

2)

empfohlener 

Drehzahlregelbereich

100 min

-1

 ...  

Nenndrehzahl

Nenndrehzahl

3220 U/min

Maximal zulässiger 

 

Dauerstrom

4,6 A

Max. Spitzenstrom in der

Motorphase

12 A (für 77 sec. @20°C)

2)

 Das Nenndrehmoment ist abhängig von der Wärme

-

abführung des Motors. Deshalb sind die Nenndrehmo-

mente gemessen nach VDE/EN.

Werte für abweichende Betriebsspannungen sind den 

entsprechenden Spezifikationen zu entnehmen. Diese 

sind auf Anfrage erhältlich.

 

Überschreiten der maximal zulässigen  

 Dauerströme!

 

Die Folge:

 

Kann zur Zerstörung des Antriebs    

 führen. 
 

► Die maximal zulässigen Dauerströme

 

 

   beachten! 

VORSICHT

 

Exceeding of the maximum permitted  

 

continuous current!

 

Consequence:

 

 

The drive may be  

   destroyed.
 

► Mind the maximum permitted  

 

 

  continuous current!

 

CAUTION

Содержание Dunkermotoren BG65Sx25 MI

Страница 1: ...th freely programmable motion controller integrated Betriebsanleitung Motor mit integriertem frei programmierbaren Motioncontroller Dunkermotoren GmbH Allmendstra e 11 D 79848 Bonndorf Schwarzwald www...

Страница 2: ...stment motor connector 21 8 2 Electrical Installation 22 8 2 1 Electro magnetic compatibility 22 8 2 2 Ground wire 22 1 Inhalt 2 ber dieses Dokument 5 3 Allgemeine Beschreibung 6 3 1 Motorbaureihe BG6...

Страница 3: ...ng Ausserbetriebsetzung und 30 Entsorgung 10 2 Service Support 31 10 3 Lieferumfang und Zubeh r 31 10 4 Download PDF Daten 31 8 2 3 Power and logic supply 23 8 2 4 Pin Assignment 23 8 2 5 Mating conne...

Страница 4: ...4 www dunkermotoren de Version 05 2017...

Страница 5: ...e commissioning it is essential that the safety instructions in the relevant section are read and understood and then observed Non observance can result in danger to persons or damage to the machine D...

Страница 6: ...e with an integrated freely pro grammable motion controller and CANbus inter face CANopen Drive Profile DSP 402 The drive has an incremental encoder with a resolution of 4096 increments per revolution...

Страница 7: ...lregelung SVEL Mode Schnelle Drehzahlregelung als untergelagerter Dreh zahlregler f r bergeord nete Positioniersysteme z B CNC Steuerungen Term Explanation Baud rate Speed of transmission or communica...

Страница 8: ...achine guideline EMC guideline and Conformity available for download on www dunkermotoren com 3 3 Bestimmungsgem e Verwendung Der Motor BG65S MI ist ein Zulieferteil und darf in der beschriebenen Konf...

Страница 9: ...ung und Transport nach den entsprechenden Vorgaben voraus Lagern Sie bitte den Antrieb gesch tzt vor Staub Schmutz und Feuchtigkeit Achten Sie auch auf die Lagerbedingungen z B Lagerungstemperatur Sie...

Страница 10: ...end IP65 eingesetzt werden Maximal zul ssige Radialkraft einzeln nicht mit Axialkraft kombiniert bei Nenndrehzahl Angriffspunkt 15mm ab Flansch 5 Technical data accessories 5 1 Electrical data Non des...

Страница 11: ...mperaturen 60 C sollten die max Lagerbelastungen nicht ausgenutzt werden Bei Getriebemotoren sind die entsprechenden Daten der Dokumentation zum Getriebes zu entnehmen HINWEIS The permissible shaft lo...

Страница 12: ...BG65Sx25 MI Nennspannung 24 V Nennleistung 176 W Nenndrehmoment 41 6 Ncm 2 empfohlener Drehzahlregelbereich 100 min 1 Nenndrehzahl Nenndrehzahl 3065 U min Maximal zul ssiger Dauerstrom 7 3 A Max Spit...

Страница 13: ...eichende Betriebsspannungen sind den entsprechenden Spezifikationen zu entnehmen Diese sind auf Anfrage erh ltlich BG65Sx50 MI Nominal voltage 24 V Nominal power 233 W Nominal torque 49 5 Ncm 2 Recomm...

Страница 14: ...nth lt die CD Rom weitere Dokumente zum Profil DSP 402 Objektverzeichnis Parametierliste SNR Software 16597 57020 SNR Starterkit mit Software 96800 05024 5 5 Optional attachments Worm gear The worm ge...

Страница 15: ...nputs and outputs which are used for example to give the start signal to run the specified profile 6 Betriebsarten Unter anderem sind folgende Betriebsarten m glich Current mode Velocity mode Position...

Страница 16: ...led by a CAN master via the CAN bus The servo motor receives its run commands from the CAN master through the CAN network 6 3 CAN open Betrieb mit abgespeichertem Fahrprofil F r diese Betriebsart kann...

Страница 17: ...Logikversorgung Wenn die Spannung f r die Logikversorgung 50V berschreitet schaltet die Leistungsstufe ab Der Fehler kann best tigt werden nachdem die Spannung unter 50V gefallen ist 7 Protective fun...

Страница 18: ...the power stage supply voltage has fallen below 60V 7 6 Over current I t The motor current phase current is monitored by an I t protection function and limited if necessary The monitoring function co...

Страница 19: ...lc SW calc Voltage controlled braking 54 V 54 V Ballast circuit 52 V 50 V 7 7 Ballastschaltung Der Antrieb besitzt einen 4Q Regler Somit kann beim Bremsen Energie zur ckgef hrt werden wodurch die Vers...

Страница 20: ...ngle adjustment motor connector power supply Vor der Inbetriebnahme sind unbe dingt die Sicherheitshinweise zu lesen und zu beachten Eine Nichtbeachtung kann zu Gefahren bei Personen oder Besch digung...

Страница 21: ...binden des Kabels mit dem Motor achten Sie auf das Symbol H Siehe Zeichnung 8 1 2 Motor connector connection During connecting of the cable with the motor note symbol H see drawing Stecker in Richtung...

Страница 22: ...g lichkeit der Anlage gepr ft und sichergestellt werden 8 1 3 Angle adjustment motor connector Adjust the angle of the motor connector in the following way Open the grub screw M3 with an allen key 1...

Страница 23: ...tage ist das Motor geh use ber eine separate Erdleitung mit der Maschinenerde zu verbinden Required measures To achieve compliance with the standards the follow ing measures are necessary For complian...

Страница 24: ...8 2 4 Pin Assignment 8 2 3 Leistungs und Logikversorgung Stecker Rundstecker M16 15 polig 8 2 4 Steckerbelegung Logic Logik 24 V DC A C Power Leistung 24 40 V DC GND 9 0 V Ballast Connector Pin B Ball...

Страница 25: ...3 IN2 brown 4 IN3 green 5 IN4 grey 6 N C 7 AI pink 8 AI violet 9 UC red 10 OUT1 black 11 OUT2 red blue 12 OUT3 white 8 2 5 Gegenstecker mit Anschlussleitung Anschlusskabel M16 Sachnummer 27573 41020 8...

Страница 26: ...onnection CAN field bus connection 8 2 8 Mating connector with cable Connecting cable Article code 16597 57033 CAN high CAN low 8 2 7 Anschluss CAN Feldbusanschluss 8 2 8 Gegenstecker mit Anschlusslei...

Страница 27: ...ents of EN 55014 1 interfe rence voltage on conductors for AC connections a power supply with at least 15dB damping has to be used e g 24V QS40 244 company Puls 40V QS40 361 company Puls 8 2 9 Elektro...

Страница 28: ...llte die Versorgung getrennt von den Signalen in einem separat geschirmten Kabel verlaufen Bei der Verwendung von Leitungen von Dunkermotoren ist die Schirmung breit fl chig im Schaltschrank aufzulege...

Страница 29: ...chaltbild erfolgen Der grau hinterlegte Ausschnitt des Prinzipschaltbildes zeigt die Anschl sse eines BG65S MI Es k nnen auch mehrere BG Motoren wie dargestellt hinterei nander geschaltet werden 1 Der...

Страница 30: ...f the digital inputs NPN Input 1 Optional for ground switching inputs 8 4 Analog inputs 8 4 1 Schematic circuit of the analog input 8 5 Digital outputs 8 5 1 Schematic circuit of the digital outputs L...

Страница 31: ...eweiligen Landes m ssen hierzu beachtet werden 9 Commissioning All drives of the series BG 45 MI are applied for custo mer projects this requires a special commissioning manual depending on the custom...

Страница 32: ...848 Bonndorf Telephone 49 7703 930 0 Fax 49 7703 930 210 E Mail info dunkermotoren de 10 3 Scope of delivery and accessories As quoted 10 4 Download PDF Data www dunkermotoren de 10 2 Service Support...

Отзывы: