ThePoint Series
18
2.10.3 Manual Calibration modes #7, and 8 (Continued)
Configuration
Settings
Adjustment
Potentiometer
RED LED
Notes
Fail Safe = High Level
Time delay set to zero
(full counter clockwise – DO
NOT FORCE PAST STOP)
Time delay action = either
Turn counter clockwise
until RED LED is ON
RED LED ON
Material being measured
must be below sensor at
least twelve inches
Turn clockwise until
RED LED just goes OFF
RED LED OFF
Turn Adjustment
Potentiometer Clockwise
the number of turns
indicated in the table below
for your material type
RED LED OFF
Manual Calibration
When material level
can not
be moved
Make certain that ThePoint is in manual calibration mode #7
or 8 See Section 2.10.4
Material Being Measured
Mode #7
(Standard Sensitivity)
Mode # 8
(High Sensitivity)
Conductive Materials (Water-Based) see note #1
15 Turns(Note 2)
20 Turns
Insulating Liquids, Organics, Oil, Plastics
1/2 Turn
2 Turns
Granular/Solid materials above 50#/ft3
1/2 Turn
2 Turns
Granular/Solid materials 25-50#/ft3
1/2 Turn
1 Turn
Granular/Solid materials less than 20#/ ft3
Use High Sensitivity Mode #8
3/4 Turn
Moist Granular Plugged Chute Applications using
flush mount 700-0207 series sensing element
(See Note 3)
1 turn
4 turns
Dry Granular Plugged Chute Applications using
flush mount 700-0207 series sensing element
Use High Sensitivity Mode #8
½ turn
Calibration is Complete
Содержание ThePoint Series
Страница 4: ...Contents...
Страница 6: ...Section 1...
Страница 28: ...ThePoint Series 22 Section 3...
Страница 36: ...Section 4...
Страница 39: ...Control Drawings 33 Section 5 Control Drawings 5 1 FM FMc Control Drawings...
Страница 40: ...ThePoint Series 34 5 1 FM FMc Control Drawings Continued...
Страница 41: ...Control Drawings 35 5 1 FM FMc Control Drawings Continued...
Страница 42: ...ThePoint Series 36 5 1 FM FMc Control Drawings Continued...
Страница 43: ...Control Drawings 37 5 1 FM FMc Control Drawings Continued...
Страница 44: ...ThePoint Series 38 5 1 FM FMc Control Drawings Continued...
Страница 45: ...Control Drawings 39 5 1 FM FMc Control Drawings Continued...
Страница 46: ...ThePoint Series 40 5 1 FM FMc Control Drawings Continued...
Страница 47: ...Control Drawings 41 5 1 FM FMc Control Drawings Continued...
Страница 48: ...ThePoint Series 42 5 1 FM FMc Control Drawings Continued...
Страница 49: ...Control Drawings 43 5 1 FM FMc Control Drawings Continued...
Страница 50: ...ThePoint Series 44 5 2 ATEX Control Drawings...
Страница 51: ...Control Drawings 45 5 2 ATEX Control Drawings Continued...
Страница 52: ...ThePoint Series 46 5 2 ATEX Control Drawings Continued...
Страница 55: ...Control Drawings 49 5 2 ATEX Control Drawings Continued...
Страница 56: ...ThePoint Series 50 5 3 Heavy Duty Spark Protection...
Страница 57: ...Control Drawings 51 5 3 Heavy Duty Spark Protection Continued...
Страница 58: ...ThePoint Series 52 5 4 Adding a Padded Capacitor...
Страница 59: ...Control Drawings 53 5 4 Adding a Padded Capacitor Continued...
Страница 60: ...ThePoint Series 54 5 4 Adding a Padded Capacitor Continued...
Страница 61: ...Control Drawings 55 5 5 Dual Seal Assembly for 700 Series Sensing Elements...
Страница 62: ...ThePoint Series 56 5 5 Dual Seal Assembly Continued...
Страница 63: ...Control Drawings 57 5 5 Dual Seal Assembly Continued...
Страница 64: ...Appendix A...
Страница 69: ......