14.  Do not operate Meter if under the 

influence of alcohol or drugs.  Read 
warning labels on prescriptions to 
determine if your judgment or reflexes 
are impaired while taking drugs. If there 
is any doubt, do not operate the Meter.

15.  People with pacemakers should 

consult their physician(s) before 
use.  Electromagnetic fields in close 
proximity to heart pacemaker could 
cause pacemaker interference 
or pacemaker failure.

16.  Do not test voltage on circuits 

higher than 600 volts.

17.  Do not test current on circuits 

higher than 600A.

18.  Dress properly.  Protective, 

electrically nonconductive 
clothes and nonskid footwear are 
recommended when working.

19.  Wear ANSI-approved safety 

goggles during use.

20.  Only use accessories intended 

for use with this Meter.

21.  Avoid damaging Meter. Use only 

as specified in this manual.

22.  Prior to testing resistance, diodes, 

or continuity; disconnect all power 
to the circuit and discharge all 
high-voltage capacitors.

23.  Performance of this Meter may vary 

depending on battery condition.

24.  Use the proper settings, terminals, 

techniques, and range for the 
tests performed.  Start with the 
range stated in the instructions.

25.  Do not apply voltage to the Test 

Leads when the Meter is in the 
Ohms testing setting.  Damage 
can occur to the Meter.

26.  Do not switch between testing modes 

with the Meter connected to a circuit.

27.  Do not use the Meter at a setting 

marked as blank on the scale.

28.  Have the Meter calibrated by a 

qualified technician every year 
to maintain accurate results.

29.  Do not disassemble Meter; take 

it to a qualified technician when 
service or repair is required.

30.  The warnings, cautions, and 

instructions discussed in this 
instruction manual cannot cover all 
possible conditions and situations 
that may occur. It must be understood 
by the operator that common sense 
and caution are factors which cannot 
be built into this product, but must 
be supplied by the operator. 

 SAVE THESE INSTRUcTIONS.

Содержание 64013

Страница 1: ...ence 17i When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2017 by Harbor Freight Tools All...

Страница 2: ...sed to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Indicates a hazardous situation which if not avoided will resul...

Страница 3: ...them c The battery is low d Near any explosive gasses or fumes e Any abnormal operation is detected If in doubt about the condition of the Meter have it serviced before use f The battery cover is ope...

Страница 4: ...Prior to testing resistance diodes or continuity disconnect all power to the circuit and discharge all high voltage capacitors 23 Performance of this Meter may vary depending on battery condition 24...

Страница 5: ...40M Resistance Accuracy 400 4M 1 0 of rdg 5D 40M 2 0 of rdg 5D Continuity Meter beeps at 50 20 Capacitance Ranges 5nF 50nF 500nF 5 F 50 F 100 F Capacitance Accuracy 5 0nF 4 0 of rdg 5D 50nF 100 F 3 0...

Страница 6: ...ction at the beginning of this manual including all text under subheadings therein before set up or use of this product Functions Non contact Voltage Indicator AUTO current clamp Rotary Switch Backlig...

Страница 7: ...NANcE SETUp Display AUTO Symbol Description AUTO Auto Range Direct Current Alternating Current Low Battery c F Celsius Fahrenheit Percentage duty cycle Hz kHz Hertz frequency MV V Volts Voltage A mA A...

Страница 8: ...ding will be held on the Display The symbol appears 2 Press again to release the hold Manual Range The Meter s default range is AUTO To select manual range press RAN Each press of the button increases...

Страница 9: ...ded conductor If detected voltage is 110V AC Meter will beep and the Non Contact Voltage Indicator will flash WARNING Even if no indication is given voltage may still be present Do not rely solely on...

Страница 10: ...id electric shock use only one hand to hold Meter when measuring current WARNING Remove Test Leads before taking measurements with the Current Clamp Note Amperage is always tested in series with circu...

Страница 11: ...0 VAC rms 42 VAC peak or 60 VDC Voltages this high present a risk of electric shock 1 Plug black test lead into cOM Jack Plug red test lead into INpUT Jack 2 Turn Rotary Switch to the position 3 Press...

Страница 12: ...isplay If measured resistance is less than 50 20 Meter will beep 6 When testing is complete turn Rotary Switch to OFF remove Test Leads and store with Meter capacitance Measurements Measure capacitanc...

Страница 13: ...ic shock turn off all power and fully discharge capacitors on the circuit under test before measuring Note When measuring Ohms start with the lowest range if the resistance is unknown 1 Plug black tes...

Страница 14: ...e mode Connect the test leads across the circuit to be measured 7 Read measured duty cycle on the Display 8 Press Hz again to return to voltage mode 9 When testing is complete turn Rotary Switch to OF...

Страница 15: ...use for long periods 3 Store unit in a dry location 4 Other than the batteries there are no replaceable parts on this unit Repairs should be done by a qualified technician Battery Replacement If the s...

Страница 16: ...from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRE...

Отзывы: