INDICATOR LIGHTS 

The operating condition of the pump is indicated by the green and red indicator 
lights on the pump control panel.

Indicator lights 

________________________________________________________________ 
Indicator lights___________________________________________________                           

    Fault                 Operation                         Description 

    (red)____           (green)___________________________________________

     Off                       Off                 The electricity supply has been switched off.                           
________________________________________________________________ 
     Off                Permanently        The pump is operating.         
                                  on 
________________________________________________________________                           
   Permanently          Off                The pump has stopped because of a fault.    
           on                                        Restarting will be attempted (it may be  
                                                       necessary to restart the pump by resetting 
                                                       the fault indication). 
                                                       Possible causes: 

                                                  * Too high motor temperatures     
                                                  *  Undervoltage 
                                                  *  Overvoltage 
                                                  *  Too many restarts (after faults) 
                                                  *  Overload                                         

________________________________________________________________ 
Permanently      Permanently        The pump is operating, but it has been  
        on                      on                 stopped because of a fault.    
                                                       Reset the fault indication or switch off    
                                                       the electricity supply. 
 ________________________________________________________________                           

      Note: See Setting By Means Of Control Panel on page 10-12, for information  
                on resetting the fault indication and stopping/starting the pump.

Содержание CHIE VARIABLE SPEED BOOSTER PUMP SYSTEM

Страница 1: ...N 98 0118 Rev B 28OCT10 CHIE VARIABLE SPEED BOOSTER PUMP SYSTEM OPERATION MAINTENANCE MANUAL Manufactured With Pride In The USA www ameriwater com 800 535 5585 AmeriWater 3345 Stop 8 Rd Dayton OH 4541...

Страница 2: ...STARTUP 5 MAINTENANCE 6 PRELIMINARY CHECKS MEASURING VOLTAGE CURRENT 6 TROUBLE SHOOTING THE PUMP 6 VALVES 6 INDICATOR LIGHTS 7 SETTING BY MEANS OF CONTROL PANEL 8 SETPOINT SETTING PUMP IN CONTROLLED...

Страница 3: ...motor and electronics the following must be observed Place the pump in such a way that sufficient cooling is ensured The temperature of the cooling air must not exceed 40 degrees C Cooling fins and fa...

Страница 4: ...eakage current 3 5 mA The leakage currents are measured in accordance with EN 60 355 1 8 The motor requires no external motor protection The pump is overvoltage protected 9 Supply voltage 1 x 208 230V...

Страница 5: ...r at least 5 minutes Pressure Sensor Installation With the protective cover off bring the wire from the pressure sensor into the motor through the strain relief in the middle Connect the yellow green...

Страница 6: ...4 SYSTEM DESIGN DRAWING...

Страница 7: ...n the pump sleeve See Plug drawing Slowly open the suction valve See System Design drawing in the inlet pipe until a steady stream of liquid runs out of the priming port Warning The escaping liquid ma...

Страница 8: ...sure TROUBLE SHOOTING THE PUMP Before removing the terminal box cover make sure that the electricity supply has been switched off Warning The pumped liquid may be scalding hot and under high pressure...

Страница 9: ..._______________________________________________ Permanently Off The pump has stopped because of a fault on Restarting will be attempted it may be necessary to restart the pump by resetting the fault i...

Страница 10: ...motor for any length of time may cause burns Only the buttons should be touched to avoid injury The pump control panel incorporates the following buttons and indicator lights CONTROL PANEL The desired...

Страница 11: ...ivated indicating a desired setpoint of 3 bar The setting range is equal to the sensor measuring range see sensor nameplate Setpoint set to 3 bar pressure control mode The buttons on the pump control...

Страница 12: ...ys By briefly pressing the up or down button on the pump This will not change the setting of the pump A fault indication cannot be reset by means of the up or down button if the buttons have been lock...

Страница 13: ...11 REPLACEMENT PARTS DRAWING...

Страница 14: ...to cause cancer birth defects or other reproductive harm One such chemical is Vinyl Chloride a compound used to produce Polyvinyl Chloride PVC The AmeriWater system you have purchased may contain PVC...

Отзывы: