background image

12

  WARNING 

This product can expose you to chemicals such as vinyl chloride (used in the 
production of PVC) or Nickel (used in the production of stainless steel), that 
are known to the State of California to cause cancer.  For more information go 
to www.P65Warnings.ca.gov.

Dear Valued Customer, 

California Proposition 65 (Prop 65) is the Safe Water and Toxic Enforcement Act of 
1986.  The State of California began enforcing amendments to California Prop 65 at 
the end of August 2018.  Prop 65 requires manufacturers to provide a clear and 
reasonable warning to residents of California about chemicals used in products that 
they purchase that are included on the Prop 65 Chemical List.  The chemicals 
included on the list are chemicals that are known to the State of California to cause 
cancer, birth defects, or other reproductive harm.  One such chemical is Vinyl 
Chloride, a compound used to produce Polyvinyl Chloride (PVC).  The AmeriWater 
system you have purchased may contain PVC or stainless steel parts. 
While warnings are only required in the State of California, AmeriWater has initiated 
the use of Prop 65 labeling for all products to ensure compliance with California 
regulations.  Please note that the above warning does not necessarily mean that the 
product that you have purchased is unsafe.  Products that have been cleared for 
market by FDA have been determined to be safe and effective by the United States 
Food and Drug Administration.  The warning is simply a requirement by the State of 
California.  If you wish to obtain additional information, please visit: 
p65warnings.ca.gov.  You may also contact your AmeriWater representative if you 
have any questions. 

Thank you for your understanding and we look forward to continuing to serve you. 

Содержание CHIE VARIABLE SPEED BOOSTER PUMP SYSTEM

Страница 1: ...N 98 0118 Rev B 28OCT10 CHIE VARIABLE SPEED BOOSTER PUMP SYSTEM OPERATION MAINTENANCE MANUAL Manufactured With Pride In The USA www ameriwater com 800 535 5585 AmeriWater 3345 Stop 8 Rd Dayton OH 4541...

Страница 2: ...STARTUP 5 MAINTENANCE 6 PRELIMINARY CHECKS MEASURING VOLTAGE CURRENT 6 TROUBLE SHOOTING THE PUMP 6 VALVES 6 INDICATOR LIGHTS 7 SETTING BY MEANS OF CONTROL PANEL 8 SETPOINT SETTING PUMP IN CONTROLLED...

Страница 3: ...motor and electronics the following must be observed Place the pump in such a way that sufficient cooling is ensured The temperature of the cooling air must not exceed 40 degrees C Cooling fins and fa...

Страница 4: ...eakage current 3 5 mA The leakage currents are measured in accordance with EN 60 355 1 8 The motor requires no external motor protection The pump is overvoltage protected 9 Supply voltage 1 x 208 230V...

Страница 5: ...r at least 5 minutes Pressure Sensor Installation With the protective cover off bring the wire from the pressure sensor into the motor through the strain relief in the middle Connect the yellow green...

Страница 6: ...4 SYSTEM DESIGN DRAWING...

Страница 7: ...n the pump sleeve See Plug drawing Slowly open the suction valve See System Design drawing in the inlet pipe until a steady stream of liquid runs out of the priming port Warning The escaping liquid ma...

Страница 8: ...sure TROUBLE SHOOTING THE PUMP Before removing the terminal box cover make sure that the electricity supply has been switched off Warning The pumped liquid may be scalding hot and under high pressure...

Страница 9: ..._______________________________________________ Permanently Off The pump has stopped because of a fault on Restarting will be attempted it may be necessary to restart the pump by resetting the fault i...

Страница 10: ...motor for any length of time may cause burns Only the buttons should be touched to avoid injury The pump control panel incorporates the following buttons and indicator lights CONTROL PANEL The desired...

Страница 11: ...ivated indicating a desired setpoint of 3 bar The setting range is equal to the sensor measuring range see sensor nameplate Setpoint set to 3 bar pressure control mode The buttons on the pump control...

Страница 12: ...ys By briefly pressing the up or down button on the pump This will not change the setting of the pump A fault indication cannot be reset by means of the up or down button if the buttons have been lock...

Страница 13: ...11 REPLACEMENT PARTS DRAWING...

Страница 14: ...to cause cancer birth defects or other reproductive harm One such chemical is Vinyl Chloride a compound used to produce Polyvinyl Chloride PVC The AmeriWater system you have purchased may contain PVC...

Отзывы: