17
115V Mini-Split
Binding the Pipes and Cables
Note:
The refrigeration lines shall be insulated separately to prevent heat transfer between the
two lines. Both lines shall be insulated.
1. Bind the insulated refrigerant pipes, power cord and drain hose with a band.
2. Reserve a length of drain hose and power cord for installation when binding them. Leave room
to separate the drain hose from the power and pipe connections for the outdoor unit.
3. Wrap them evenly.
4. The liquid pipe and gas pipe should be bound separately at the end.
5. When possible, keep the power cord and communication lines separated.
6. The drain hose should be bound at the bottom.
indoor unit
gas
pipe
indoor and
outdoor power cord
liquid pipe
drain hose
band
drain hose band
connection pipe
indoor power cord
Hanging the Indoor Unit
Note:
It is recommended the indoor unit be mounted on a non-porous flat surface. Doing so will
reduce unfiltered air from entering the unit as well as reduce sweating behind the unit. Assure
the insulation sections surrounding the refrigeration and condensate line are sealed and without
cracks or openings.
1. Insert the bound pipes and wires into the wall sleeve and pass through to the outside.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and the wall hole or sleeve with sealing material.
4. Secure the wall pipe bundle with saddles.
5. Check if the indoor unit is installed securely and snugly to the wall.
6. Do not bend the drain hose too excessively in order to prevent blockage.
sleeve
upper hook
lower hook of
wall-mounting frame