Installing the Condensate Pipe
NOTICE
Do not wrench or bend the drain hose and make sure the ends of the condensate pipe are not
under water. Failure to do so could result in leakage.
Outlet
pipe
Drain hose
Drain hose
Tape
Outlet pipe
Drain hose
Insulating pipe
1. Connect the drain hose to the outlet pipe of the indoor unit (as shown in Fig. A below).
2. Bind the joint with tape (as shown in Fig. B below).
3. Wrap the pipe with insulating tape to prevent condensation (as shown in Fig. C below).
Fig. A
Fig. B
Fig. C
Wiring at the Indoor Unit
1. Open the front panel of the indoor unit, remove the screw on the wiring cover and remove the
cover (as shown in Fig. D below).
2. Thread the power connection wire through the cable-cross hole at the back of the indoor unit
and pull it through to the front side (as shown in Fig. E below).
wiring cover
screw
panel
power connection
wire
cable-cross
hole
Fig. D
Fig. E