Appendix

Appendix

Maintenance

Code Blue

Operation

Contr

ol Station

Clock/Timer

Appendix 3
Operator's Flowchart

To Set Time

UP/CLOCK/DOWN switch in 

CLOCK

 position

SET/RUN switch in 

SET

 position

Clock display 24Hr or 12Hr
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing hours 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing minutes 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing seconds 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Display shows 

DONE

Place SET/RUN switch in 

RUN

 

position

To Use as a Clock

Place SET/RUN switch in 

RUN

 

position
UP/CLOCK/DOWN switch in 

CLOCK

 position

Code Blue Operation

SET/RUN switch 

MUST

 be in 

RUN position
To stop and hold code blue time 

for viewing, press 

START/STOP

To Reset Clock/Timer to 

Normal Operation

Place SET/RUN switch 

momentarily in 

SET

 position and 

return switch to 

RUN

 position

To Set UP Counter Preset

UP/CLOCK/DOWN switch in 

UP

 

position
SET/RUN switch in 

SET

 position

Clock displays flashing hours 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing minutes 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing seconds 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Display shows 

DONE

Place SET/RUN switch in 

RUN

 

position

To Use UP Counter

UP/CLOCK/DOWN switch in 

UP

 

position
Place SET/RUN switch in 

RUN

 

position
Place 

RESET

 to display 00:00:00

Place 

START/STOP

 to Begin

Place 

START/STOP

 to Hold

Place 

START/STOP

 to begin 

again
Alarm will sound when preset 

time is reached
Press 

RESET

 to reset counter

To Set DOWN Counter Prese

t

UP/CLOCK/DOWN switch in 

DOWN

 position

SET/RUN switch in 

SET

 position

Clock displays flashing hours 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing minutes 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing seconds 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Display shows 

DONE

Place SET/RUN switch in 

RUN

 

position

To Use DOWN Counter

UP/CLOCK/DOWN switch in 

DOWN

 position

Place SET/RUN switch in 

RUN

 

position
Place 

RESET

 to display preset 

time
Place 

START/STOP

 to Begin

Place 

START/STOP

 to Hold

Place 

START/STOP

 to begin 

again
Alarm will sound  00:00:00 is 

reached
Press 

RESET

 to reset counter

START/STOP          RESET

INCREMENT          ENTER

RUN

SET

UP

DOWN

CLOCK

12 3/8

5 3/8” 

3.0”

Digital Clock/Timer

Содержание SiteSync IQ SQA261RSAES

Страница 1: ...Installation and Operation Manual Part H004242 Rev 4 October 2011 Wireless Digital Clock Elapsed Time Indicator with Code Blue...

Страница 2: ...tive Devices CAUTION This equipment contains electronic devices that are sensitive to static electric charges To guarantee protection for the circuitry of this unit it is required that electrostatic h...

Страница 3: ...et Time 10 Down Counter Elapsed Time Operation 10 Code Blue Description 11 11 Operations 11 Wiring 11 Important Considerations 12 Operating Maintenance 13 Cleaning 13 Battery Maintenance 13 System Mai...

Страница 4: ...set Both timer modes have a programmable preset value When the timer reaches the preset value a two second audible alarm sounds from a speaker in the control station The clock control station contains...

Страница 5: ...n gang box G hot neutral ground wires to non switched electrical circuit wiring using UL approved wire nuts Route field wiring away from sharp projections corners and internal components For Molex whi...

Страница 6: ...ing Appendix Maintenance Code Blue Operation Control Station Clock Timer K2 K2 K1 K1 12VAC 12VAC UNREG GND PIEZO S5 S4 S3 S2 S1 CHASSIS NEUTRAL 120VAC MASTER CLOCK TERMINAL BLOCK Typical wiring for th...

Страница 7: ...an SQA261RSAEA Master Clock connect the 3 Interconnecting Wires J from the SQA261RSAES Slave Clock using UL approved wire nuts z Mount back cover A to electrical box D using 2 screws single gang or 4...

Страница 8: ...er mode Clock Position This position is used to choose clock mode Down Position This position is used to choose down counting elapsed timer mode Start Stop Increment Switch This button is used to star...

Страница 9: ...field wires into the double gang box v Connect field wiring interconnecting the ATSTCS Control Station with the Digital Clock Timer to the appropriate wires of the Control Station See wiring detail b...

Страница 10: ...24 hour mode option is configured by the display settings of the system controller The ATSTCS control station will allow the user to set a 12 or 24 mode and time when the SET RUN switch is in the SET...

Страница 11: ...n v Set the SET RUN switch to the SET position The hours digits will be flashing w Using the INCREMENT switch set the desired hours for the preset time then press ENTER The minutes digits will now be...

Страница 12: ...d the time held for viewing by pressing the START STOP button on the ATSTCS switch panel The Code Blue timer cannot be restarted from the switch panel To reset the clock back to normal operation the R...

Страница 13: ...nals initiates a Code Blue If the Code Blue contact opens and closes again before the clock timer is reset back to normal operation the Code Blue timer will start over from 00 00 00 If a power failure...

Страница 14: ...be erased by deeply discharging the battery and recharging it It is recommended that the operator remove 120vac power from the Digital Clock Timer once per year for at least four hours nNote There is...

Страница 15: ...be changed and the alarm will not sound Appendix 2 Using the Digital Clock Timer as a Count Down Elapsed Timer Only For applications where the user does not want to use the clock and up count function...

Страница 16: ...to change Push ENTER Clock displays flashing minutes digits Push INCREMENT to change Push ENTER Clock displays flashing seconds digits Push INCREMENT to change Push ENTER Display shows DONE Place SET...

Отзывы: