background image

Installation Instr

uctions

In

s

ta

ll

a

ti

o

n

 I

n

s

tr

u

c

ti

o

n

s

Certified to comply with ASME A112.18.1

© 2017 American Standard

NOTE TO INSTALLER: Please give this manual to the customer after installation.

NOTE TO INSTALLER: Please give this manual to the customer after installation.

To learn more about American Standard Selectronic

®

 Products visit our website at: 

www.americanstandard-us.com

or e-mail us at: 

[email protected]

For Parts, Service, Warranty or other Assistance,

please call

 

(844) CRT-TEAM / (844) 278-8326  

(In Canada: 1-800-387-0369)

(In Toronto Area only: 1-905-306-1093)

SELECTRONIC

®

Integrated Faucet with 
Above-Deck Mixing

705X.105
705X.115

705X.205
705X.215

MODEL NUMBERS

Product No.'s & Options

Specifications

Faucet Installation

Electrical Installation

Start-up / Maintenance

FAQ’s / Troubleshooting

Parts

1

2

2

3-4

5-9

9-10

11

CAUTION:

  Use only American Standard supplied 

transformers and cable sets. Using non-AS 
supplied cables, or cutting, splicing or modifying 
any components will void the warranty.

M965654 Rev. 2.2 (12/17)

Содержание SELECTRONIC 705X.105

Страница 1: ...americas com For Parts Service Warranty or other Assistance please call 844 CRT TEAM 844 278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SELECTRONIC Integrated Faucet with Above...

Страница 2: ...below deck User adjustable above deck mixing uses ceramic disc valve for dependability long life Mixing handle can be removed for one time temperature setting during installation Installation Instruct...

Страница 3: ...through hole in ESCUTCHEON with PUTTY PLATE 2 and mounting surface Make sure PIN 6 is in back 3 Assemble RUBBER WASHER 7 BRASS WASHER 8 and THREADED LOCKNUT 9 onto SHANK 4 from underside of sink or mo...

Страница 4: ...enter lines as shown 4 Place the BRACKET 5 on the horizontal center line and mark the location of the mounting holes to be drilled 5 Using 1 4 diameter drill bit drill two mounting holes aproximately...

Страница 5: ...structions refer to section B page 3 For subsequent Units refer to instructions below C 1 Connect one end of the 10 EXTENSION 1 to the available terminal of the previous unit s Y ADAPTER 2 and the oth...

Страница 6: ...LINE FILTER 3 on each wall supply outlet Be sure that INLINE FILTER 3 is inserted in the correct direction See Illustration 3 Connect HOT FLEXIBLE SUPPLY marked with red stripe 1 to INLINE FILTER 3 on...

Страница 7: ...tion and hold in place until the LED begins to blink again Fig 4a 5 Once the SENSOR CONTROL LED 2 begins to blink again remove your hand from the detection zone When the flashing stops the detection d...

Страница 8: ...a 2 5mm HEX WRENCH Remove SENSOR ASSEMBLY 2 from FAUCET SPOUT 3 Remove O RING 5 Remove SENSOR 2a from CARRIER 4 and replace with new SENSOR 2a Replace O RING 5 Install SENSOR ASSEMBLY 2 into FAUCET SP...

Страница 9: ...hten See Fig 2 in this section CLEAN FILTER SCREEN ON SOLENOIDVALVE Fig 8 9 D 1 Remove the FAUCET SPOUT 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET SPOUT...

Страница 10: ...not open and sensor will continuously blink 2 times interrupted by a pause for up to 7 days Q Why has the flow rate of the faucet reduced significantly A The filter assembly flow regulator or areator...

Страница 11: ...FUNCTION 1 1 2 2 YES YES NO NO YES NO OPEN EXTERNAL SUPPLY STOPS CRITICALLY LOW BATTERY INSTALL NEW BATTERY DEAD BATTERY INSTALL NEW BATTERY REPEAT NO CHECK FOR DAMAGE TO SENSOR WIRE INSULATION REPLA...

Отзывы: