background image

11

6

1. 

Remove the four COVER SCREWS 

(1)

 and COVER 

from 

(2)

 ELECTRICAL BOX 

(4)

Fig. 10.

 

2.

 Pull the CIRCUIT BOARD 

(3)

 out from ELECTRICAL 

BOX (4). 

Fig. 10.

3.

 Knock out lower blank in ELECTRICAL BOX 

(4) 

with 

flat blade screwdriver.  Install from the back of 
ELECTRICAL BOX 

(4)

 the POWER SUPPLY GROMMET 

(8)

Fig. 10a.

4.

 Attach the SAFETY CHAIN 

(5)

 from the FRONT 

PANEL 

(6)

 to the MOUNTING POST 

(7)

 as shown.

Feed the Red and Black wires through the back opening 
in the ELECTRICAL BOX 

(4)

.  

Fig. 10a.

5. 

From back of

 

ELECTRICAL BOX 

(4)

 remove SPLIT 

PLUG 

(8a)

 from POWER SUPPLY GROMMET 

(8)

. Insert 

POWER CORD CONNECTOR 

(9)

 through POWER 

SUPPLY GROMMET 

(8)

. Insert POWER CORD 

(10)

 into 

SPLIT PLUG 

(8a)

. Push SPLIT PLUG 

(8a)

 into POWER 

SUPPLY GROMMET (

8)

 to seal. 

Fig. 10b.

6.

 Insert POWER SUPPLY CONNECTOR 

(9)

 into 

RECEPTOR 

(11)

 on CIRCUIT BOARD 

(3)

.

 

Install 

CIRCUIT BOARD 

(3)

 into ELECTRICAL BOX 

(4)

.

Fig. 10b.

7. 

Install the SENSOR WIRE GROMMET 

(15)

 into the 

COVER 

(2)

 as shown.

 

Remove the SPLIT PLUG 

(15a) 

from SENSOR WIRE GROMMET 

(15)

. Insert SENSOR 

WIRE CONNECTOR 

(12)

 through SENSOR WIRE 

GROMMET 

(15)

. Insert SENSOR WIRE 

(13)

 into SPLIT 

PLUG 

(15a)

. Push SPLIT PLUG 

(15a)

 into SENSOR 

WIRE GROMMET 

(15)

 to seal. 

Fig. 10c. 

8.

 Insert SENSOR WIRE CONNECTOR 

(12)

 into 

CIRCUIT BOARD RECEPTOR 

(14)

 slot. 

Fig. 10c.

9. 

Replace COVER 

(2)

. Tighten COVER SCREWS 

(1)

 

firmly.

    CONNECT FRONT PANEL TO
ELECTRICAL BOX (AC POWER);
Fig. 10

7

Fig. 10

Fig. 10a

Fig. 10b

Fig. 10c

T O P

T O P

1

2

3

4

4

4

6

5

7

3

8

9

11

9

8

15

2

15a

1

12

13

8a

10

KNOCK OUT

BLANK

BLACK &
RED WIRES

14

T O P

8

T O P

7

M968550 REV. 1.5

Содержание SELECTRONIC 6065.22 Series

Страница 1: ...8550 REV 1 5 To learn more about American Standard Faucets visit our website at www americanstandard us com or U S customer s e mail us at faucetsupport americanstandard com For Parts Service Warranty...

Страница 2: ...Plate with Sensor 4 Supply Stop 5 Sweat Solder Adapter 6 Manual Override Hoses 7a Vacuum Breaker Flush Connection Wall Mount Back Spud 7b Vacuum Breaker Flush Connection Floor Mount Back Spud T O P 8...

Страница 3: ...quate volume of water for each fixture 2 Fig 1 Roughing in Dimensions GENERAL DESCRIPTION 10 Concealed Flushometer for 1 1 2 Spud Fixtures SELECTRONIC PROXIMITY TOILET FLUSH VALVE Exclusive self clean...

Страница 4: ...1 and turn off water supply line FLUSH OUT SUPPLY LINES Fig 5 3 FOR HOLE LOCATION OF SUPPLY ON BACK INLET FIXTURES REFER TO FIXTURE BEING INSTALLED FOR CORRECT HEIGHT FROM FINISHED FLOOR 127mm 5 406m...

Страница 5: ...11 Connect the COUPLING NUT 14 to the BRASS ELBOW 12 and tighten fully Fig 6b 7 From behind the wall install the ELBOW AND TUBE ASSEMBLY 12 11 through the hole in the wall Install WALL ESCUTCHEON 16 o...

Страница 6: ...ASKET 10 is installed Note There is a 13mm 6mm 1 2 1 4 tolerance for the 121mm 4 3 4 dimension Fig 9 2 Pull the VACUUM BREAKER TUBE 7 up to meet the threaded FLUSH VALVE CONNECTION 8 and hand tighten...

Страница 7: ...T PLUG 8a Push SPLIT PLUG 8a into POWER SUPPLY GROMMET 8 to seal Fig 10b 6 Insert POWER SUPPLY CONNECTOR 9 into RECEPTOR 11 on CIRCUIT BOARD 3 Install CIRCUIT BOARD 3 into ELECTRICAL BOX 4 Fig 10b 7 I...

Страница 8: ...OR 8 into CIRCUIT BOARD RECEPTOR 10 slot Fig 11b 9 Replace COVER 2 Tighten COVER SCREWS 1 firmly 7 Fig 11a Fig 11b Fig 12 1 2 3 4 6 11 2 11a 8 9 1 CONNECT FRONT PANEL TO ELECTRICAL BOX DC POWER BATTER...

Страница 9: ...E SWITCH 3 CONNECT OVERRIDE HOSES AC DC POWER Fig 13 10 1 Push the RED WIRE CONNECTOR 1 onto the SOLENOID PIN 2 with Red Stripe Push the BLACK WIRE CONNECTOR 3 onto the other SOLENOID PIN 4 Push the w...

Страница 10: ...2 ELECTRICAL BOX 3 remove ROUND KNOCK OUT 11 on the bottom of the box by pressing a flathead screwdriver into the center of the ROUND KNOCK OUT 11 Fig 15b 8 Insert additional SENSOR WIRE GROMMET 12 in...

Страница 11: ...STOP 2 must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture The fixture must be able to handle a continuous flow in case of a flush valve failure V...

Страница 12: ...stops blinking and stays ON move your hand to the desired position from sensor detection zone 15 3 4 to 31 1 2 400 to 800mm and hold in place until the LED 6 begins to blink again Fig 19a Note Maximum...

Страница 13: ...RST 5 SECONDS NO REPLACE SOLENOID KIT RETRY AUTOMATIC FLUSH WAS IT SUCCESSFUL YES 1 COVER SENSOR FOR 10 SECONDS 2 UNCOVER SENSOR FOR 10 SECONDS REPLACE BATTERY SEE STEP 13 page 10 in manual MANUAL VAL...

Страница 14: ...8 0020A SPUD COUPLING M962751 0070A VACUUM BREAKER ASSEMBLY M962751 0070A VACUUM BREAKER ASSEMBLY A950487 0070A CIRCUIT BOARD DC A950489 0070A CIRCUIT BOARD AC MULTI AC M950169 0070A POWER SUPPLY A922...

Отзывы: