7
M965651 Rev. 2.0 (3/19)
© 2019 AS America Inc.
Unit #2
Unit #3
Fig. 3
10 ft.
EXTENSION
CABLE
AC
POWER
SUPPLY
*MAXIMUM OF 15 UNITS PER AC POWER SUPPLY.
10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
OR
Unit #1
Already installed
BLACK &
WHITE
POWER
CONNECTIONS
C
MULTI-AC VERSION (DAISY-CHAIN); Fig. 3, 3a
Important: All control box covers must be removed before beginning to make daisy-chain connections.
Disconnect the first unit’s Y-Adapter from power supply before making daisy-chain connections.
Note: For Unit #1 electrical instructions, refer to section B (page 6).
For subsequent Units, refer to instructions below...
1.
Remove COVERS from all CONTROL BOXES
(3)
.
2.
Remove solid black plug grommet from left side of all
CONTROL BOXES
(3)
, and replace with GRAY
GROMMET
(5b)
. (Supplied with each Faucet).
3.
Insert pervious unit’s 10
'
EXTENSION
(11a)
through
gray GROMMET
(5b)
and connect to single terminal
of Y-ADAPTER
(11)
.
4.
Feed CABLES
(2)
through the top of CONTROL BOX
(3)
.
Connect one CABLE
(2)
to the SOLENOID CABLE
(7)
,
and the other to either of the two available terminals of
the Y-ADAPTER
(11)
. Connect the current unit’s 10
'
EXTENSION
(10a)
to available terminal of the
Y-ADAPTER
(11)
.
5.
Feed the other end of the 10 ft.EXTENSION
(10b
)
through the two GRAY GROMMETS
(6a and 6b)
and
connect to the single terminal of the next unit’s
Y-ADAPTER
(11)
. Place Y-ADAPTER
(11)
into
CONTROL BOX
(3)
.
6
. Repeat Steps above for each additional Unit, for a
Max. of 15 Units on one AC POWER SUPPLY.
7.
Reinstall CONTROL BOX COVERS. Tighten cover
screws firmly.
CAUTION:
Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or
cutting, splicing or modifying any components will void the warranty.
Unit #2 Detail
Fig. 3a
5
5b
10b
6a
6b
10a
7
2
2
11
11a
3