4
M965651 Rev. 2.0 (3/19)
© 2019 AS America Inc.
2
MOUNT CONTROL BOX; Fig. 2
NOTE: The illustration shows the Infection Control faucet
mounted on the American Standard Infection Control
Sink. Faucet can be installed on any sink or countertop.
For futher instructions regarding faucet installation on the
American Standard Infection Control Sink, see instruction
sheet No. 7301793-100 (Infection Control Sink System)
supplied with Sink.
1.
For installation on Infection Control Sink, mount
CONTROL BOX
(1)
on MOUNTING BRACKET
(2)
with
the SCREWS
(3)
provided.
2.
For all other sinks or countertops, determine location of
CONTROL BOX
(1)
. It must be located with-in the 14
"
(356mm) by 21
"
(533mm) shaded area shown in
Figure 2
in
order for electrical connections from the spout assembly to
be made properly.
NOTE: CONTROL BOX SUPPLY HOSE is 20". Distance
between wall supply and CONTROL BOX (1) must
be taken into consideration.
3.
Remove tape from CONTROL BOX COVER
(6)
and pull off
COVER
(6)
. Hold the CONTROL BOX
(1)
in desired location
and mark the four mounting hole locations as shown.
NOTE: Find plastic bag containing 4 M5X16 screws to be
used for securing the CONTROL BOX (1) when
installation is complete.
NOTE: For AC installation, make power supply connection
before mounting CONTROL BOX (1) to wall.
4.
It is recommended that the CONTROL BOX
(1)
be secured
to a wall stud or cross brace within the wall using the
SCREWS
(3)
supplied. If the CONTROL BOX
(1)
is to be
installed on tile or plaster walls, the ANCHORS
(5)
and
SCREWS
(4)
should be used.
3
CONNECT SPOUT HOSE TO CONTROL BOX;
Fig. 3
1.
Connect SUPPLY NUT
(1)
from spout hose to nipple on top
of CONTROL BOX
(2)
. Tighten with adjustable wrench to
make a water tight connection.
Fig. 3.
4
CONNECT WATER SUPPLY TO CONTROL
BOX AND WALL SUPPLY; Fig. 4, 4a
NOTE: If using the optional Mixing Valve, see sheet
#M968808 for installation instructions.
1.
Insert FIBER WASHER
(4)
into SUPPLY NUT
(1)
on
CONTROL BOX
(2)
.
2.
Connect FLEXIBLE SUPPLY HOSE
(3)
to SUPPLY NUT
(1)
on CONTROL BOX
(2)
. Tighten to make a water tight
connection. Use two wrenches to tighten if necessary.
Fig. 4.
3.
Connect FLEXIBLE SUPPLY HOSE
(3)
directly to wall
supply. Connection on FLEXIBLE SUPPLY HOSE
(3)
is 3/8
"
compression. Use adjustable wrench to tighten connection.
Do not over tighten.
Fig. 4a.
Note:
FLEXIBLE SUPPLY HOSE
(3)
measures 20
"
from
the bottom of the CONTROL BOX
(2)
base. If additional
supply length is required, installer must purchase parts
separately.
Impor tant:
If FLEXIBLE SUPPLY HOSE
(3)
is too long, loop to
avoid kinking.
Fig. 2
3-3/4"
(96mm)
2-3/4"
(71mm)
3"
(76mm)
6
4
5
2
2
3
1
1
MOUNTING
BRACKET
SUPPLIES
WASTE
ENCLOSURE
MOUNTING
HOLES
1524mm
(60)
20"
(500mm)
MOUNTING
BRACKET
14"
(356mm)
21"
(533mm)
Fig. 3
1
2
1
3
3
Fig. 4
2
COLD WATER OR
TEMPERED
WALL SUPPLY
OTHER SINK
INSTALLATION
Fig. 4a
4