- 3 -
THIN WALL INSTALL
2
M965906 Rev. 1.2 (8/19)
CAUTION
Turn off hot and cold water
supplies before beginning.
COLD
1
2
3
HOT
10
6
n
See Roughing-in diagram before starting.
n
Finished wall should allow for a 3-1/2" diameter opening (Use PLASTER GUARD for guidance).
n
Remove PLASTER GUARD
(8)
, rotate 90˚ counter clockwise and install the two screws. (Thin wall text should be on top)
n
Use SELF-CENTERING HOLE GUIDES
(9)
as a guide for thin wall install.
n
LOCKING SCREW
(10)
keeps valve in place when installing. Completely Thread LOCKING SCREW
(10)
onto
PLASTER GUARD
(8)
.
n
During the installation, make sure to position the Locking feature screw as shown in
Figure A
below. Once the valve is
positioned on the Thin Wall, turn counterclockwise as shown in
Figure B
to secure VALVE BODY
(2)
in place.
n
Connect HOT and COLD water supplies per connection method of selected valve.
n
Connect RISER PIPE
(1)
to VALVE BODY
(2)
top outlet marked “UP”.
n
Connect TUB FILLER PIPE
(3)
to bottom outlet.
CAUTION: After valve installation, inspect the VALVE BODY for any debris. It can damage Pressure Balance
Valve cartridge.
NOTE: For back to back installation, follow steps mentioned above. Reversal of Hot/Cold water supplies is
accomplished by rotating cartridge (supplied with trim) 180° during installation.
3-1/2"
SIDE VIEW
8
9
Fig. B
Fig. A
UNLOCK
LOCK
10
10
Hex
Wrench
4 mm