18-CG03D1-4
64
STRAP
36" MAX.
APPLIANCE ADAPTER
WITH TEST PORT
APPLIANCE
AIR INTAKE CLAMP
OUTER WALL PLATE
EXHAUST
AIR INLET
INNER WALL PLATE
ILLUSTRATION # 1
TERMINAL ADAPTER
TERMINAL
AIR INTAKE CLAMP
BURNER AIR ADAPTER
BURNER
12" min. above ground
or normally expected
snow accumulation level
VENT (SLOPING DOWN OR UP)
MIN. 1/4" SLOPE/FOOT
TYPICAL INSTALLATION
INSTALLATION CONSIDERATIONS (Illustration #1)
1) The vent pipe bend radius is 12".
2) Place metal strapping every 36" to support vent pipe and prevent it from sagging.
3) Maximum wall thickness is 14". Contact the manufacturer for recommendations in
case of thicker wall.
4) This system is not designed for common venting. Use for a single appliance only
unless otherwise approved.
5) Utilize the appliance adapter test port for combustion testing required by manufacturer
s.
6) Follow national codes for the installation of oil burning equipment: in USA - NFPA 31,
in Canada - CAN/CSA-B139 and local regulations.
MAINTENANCE
The boiler manufacturer recommends the entire heating system, including the
appliance and vent, to be checked annually by a qualified heating professional.