American Dynamics RCSN422 Скачать руководство пользователя страница 2

 

SENSORNET TO RS-422 CODE CONVERTER 

8000-2593-01, REV. C 

INSTALLATION GUIDE 

2 of 7

 

Indicators, Connections, and Settings 

 

µP 485 

422 

~  

 

 

 

 

Front Panel (left to right) 

Reset Recessed 

button 

used to reset the 

code converter (use a paperclip). 

 

Green LED indicates 24Vac is applied. 

µP 

Green LED blinks when processor in 
code converter is operating. 

485 

Green LED shows SensorNet activity: 

  Off indicates no activity 

  On indicates network is active with 

valid data 

  Blinks when unit is answering polls.

 

 

Red, noise LED lights for 0.5s. Usually 
indicates invalid frame lengths or noise 
on the line.  

422 

Green LED blinks to indicate that at 
least one RS-422 device is responding 
to polls. 

  Blinks twice when unit is reset or 

powered up 

  First blink indicates a successful 

ROM check; second blink indicates 
a successful RAM check 

  LED illuminates continuously when 

either check fails, stopping the test 

  Remains illuminated during 

program load.

 

Rear Panel (left to right)

 

 

422 Ports 
(Seven) 

Each port receives a RS-422 cable 
from a dome camera or RJ-860AP  
J-Box. An RS-422 line test switch and 
LED are adjacent to each port. 

LED

Test Switch

 

Pinouts: 
Pin 1 – RXHI+ 
Pin 2 – RXLO- 
Pin 3 – TXHI+ 
Pin 4 – TXLO- 
Pin 5 – Ground

 

485 Port 

Receives a SensorNet (RS-485) cable 
from the ADTT16E or MegaPower LT. 

Terminate 
Switch 

Set to left (terminated) 
Set to right (unterminated) 

Address 
Switches 

x10

x1

 

Use address 00 for the loopback test 
(see page 4). 
If MiniDomes are used, set the device 
address to 16. If SpeedDomes are 
used, set the device address to 32. 

24Vac 
Connector 

Receives 24Vac from a transformer. 

Pinouts: 
Pin 1 – AC or common 
Pin 2 – Ground 
Pin 3 – 24Vac

 

Front 

Rear 

Pin 1 

Pin 1 

Содержание RCSN422

Страница 1: ...tallation The converter can be placed on a tabletop or installed in a rack under a shelf or on a wall Parts Supplied Install Kit 0351 1635 01 which includes Mounting Bracket 2 Screw PHP M3x8 4 Connect...

Страница 2: ...First blink indicates a successful ROM check second blink indicates a successful RAM check LED illuminates continuously when either check fails stopping the test Remains illuminated during program loa...

Страница 3: ...EU ist es f r den Betrieb durch eine begrenzte Stromquelle vorgesehen Eine begrenzte Stromquelle ist eine zertifizierte SELV Quelle Schutzkleinspannung bei inh renter Begrenzung mit einem maximalen A...

Страница 4: ...instructions For just the ping test refer to MegaPower LT operation instructions MP LTHB 1 Note If a controller requests device information from a camera having the same address as the converter the c...

Страница 5: ...L 860 AP J Box To MiniDome To Unicard SpeedDome To Optima To Optima LT To SpeedDome Ultra Pigtail To SpeedDome Ultra I O J1 10 J5 P3 P1 P7 Pin 1 TX Pin 1 RX Pin 7 RX Pin 1 RX Pin 1 RX Pin 6 RX Pin 1 R...

Страница 6: ...Dome Ultra Pigtail To SpeedDome Ultra I O J1 10 J5 P3 P1 P7 Pin 1 TX Pin 1 RX Pin 7 RX Pin 1 RX Pin 1 RX Pin 6 RX Pin 1 RX Pin 2 TX Pin 2 RX Pin 6 RX Pin 2 RX Pin 2 RX Pin 7 RX Pin 2 RX Pin 3 AC Pin 3...

Страница 7: ...y it to c program files AD_Utilities Note This file must be F2814 0102 or higher 3 Set the code converter to address 32 4 Launch the ADCASNET utility and click Load Utility 5 Click the Scan Network ic...

Отзывы: