SENSORNET TO RS-422 CODE CONVERTER
8000-2593-01, REV. C
INSTALLATION GUIDE
7 of 7
Addendum F:
Flashing Firmware on the RCSN422 Using an ADCASNET Module
Procedure
1. Download and install the ADCASNET utility from
http://www.americandynamics.net
. Click on
Support/Software Downloads/USB Control Module/USB Control Module Utilities/ADUtils_1_00.zip.
2. Download RCSN422 hex file from the web site and copy it to c:\program files\AD_Utilities (
Note:
This file
must be F2814-0102 or higher).
3. Set the code converter to address 32.
4. Launch the ADCASNET utility and click “Load Utility”.
5. Click the “Scan Network” icon; the load utility will look for the code converter on the right-hand screen.
6. Once it detects the code converter, the firmware version is displayed. For example: 2814-XXXX.
7. Click on the displayed version and then click “Load Snet Device”. A progress bar appears.
8. When complete, close the ADCASNET utility and reboot the code converter.
9. Rescan the code converter and verify firmware was updated.