SENSORNET TO RS-422 CODE CONVERTER 

8000-2593-01, REV. C 

INSTALLATION GUIDE 

7 of 7

 

Addendum F: 

Flashing Firmware on the RCSN422 Using an ADCASNET Module 

 

 

Procedure 

1.  Download and install the ADCASNET utility from 

http://www.americandynamics.net

. Click on 

Support/Software Downloads/USB Control Module/USB Control Module Utilities/ADUtils_1_00.zip. 

2.  Download RCSN422 hex file from the web site and copy it to c:\program files\AD_Utilities (

Note:

 This file 

must be F2814-0102 or higher). 

3.  Set the code converter to address 32. 

4.  Launch the ADCASNET utility and click “Load Utility”. 

5.  Click the “Scan Network” icon; the load utility will look for the code converter on the right-hand screen. 

6.  Once it detects the code converter, the firmware version is displayed. For example: 2814-XXXX. 

7.  Click on the displayed version and then click “Load Snet Device”. A progress bar appears. 

8.  When complete, close the ADCASNET utility and reboot the code converter. 

9.  Rescan the code converter and verify firmware was updated. 

Содержание RCSN422

Страница 1: ...tallation The converter can be placed on a tabletop or installed in a rack under a shelf or on a wall Parts Supplied Install Kit 0351 1635 01 which includes Mounting Bracket 2 Screw PHP M3x8 4 Connect...

Страница 2: ...First blink indicates a successful ROM check second blink indicates a successful RAM check LED illuminates continuously when either check fails stopping the test Remains illuminated during program loa...

Страница 3: ...EU ist es f r den Betrieb durch eine begrenzte Stromquelle vorgesehen Eine begrenzte Stromquelle ist eine zertifizierte SELV Quelle Schutzkleinspannung bei inh renter Begrenzung mit einem maximalen A...

Страница 4: ...instructions For just the ping test refer to MegaPower LT operation instructions MP LTHB 1 Note If a controller requests device information from a camera having the same address as the converter the c...

Страница 5: ...L 860 AP J Box To MiniDome To Unicard SpeedDome To Optima To Optima LT To SpeedDome Ultra Pigtail To SpeedDome Ultra I O J1 10 J5 P3 P1 P7 Pin 1 TX Pin 1 RX Pin 7 RX Pin 1 RX Pin 1 RX Pin 6 RX Pin 1 R...

Страница 6: ...Dome Ultra Pigtail To SpeedDome Ultra I O J1 10 J5 P3 P1 P7 Pin 1 TX Pin 1 RX Pin 7 RX Pin 1 RX Pin 1 RX Pin 6 RX Pin 1 RX Pin 2 TX Pin 2 RX Pin 6 RX Pin 2 RX Pin 2 RX Pin 7 RX Pin 2 RX Pin 3 AC Pin 3...

Страница 7: ...y it to c program files AD_Utilities Note This file must be F2814 0102 or higher 3 Set the code converter to address 32 4 Launch the ADCASNET utility and click Load Utility 5 Click the Scan Network ic...

Отзывы: